Variations in performance characteristics of commercial enzyme immunoassay kits for detection of antineutrophil cytoplasmic antibodies: what is the optimal cut off?

نویسندگان

  • J U Holle
  • B Hellmich
  • M Backes
  • W L Gross
  • E Csernok
چکیده

BACKGROUND Previous studies have shown considerable variation in diagnostic performance of enzyme linked immunosorbent assays (ELISAs) for measuring antineutrophil cytoplasmic antibodies (ANCA) specific for proteinase 3 (PR3) and myeloperoxidase (MPO). OBJECTIVE To analyse the performance characteristics of different commercially available direct ANCA ELISA kits. METHODS ELISA kits for detecting PR3-ANCA and MPO-ANCA from 11 manufacturers were evaluated. Serum samples were taken from patients with Wegener's granulomatosis (15), microscopic polyangiitis (15), other vasculitides (10), and controls (40). RESULTS were compared with data obtained by indirect immunofluorescence (IFT). The diagnostic performance of the tests was analysed and compared by receiver operating characteristic (ROC) curve analysis.Results: Applying the manufacturers' cut off resulted in great variation in sensitivity of the commercial PR3-ANCA kits for diagnosing Wegener's granulomatosis (ranging from 13.3% to 66.7%), and of the MPO-ANCA kits for diagnosing microscopic polyangiitis (ranging from 26.7% to 66.7%). Specificities were relatively constant (from 96.0% to 100%). IFT was superior to all ELISAs (C-ANCA for Wegener's granulomatosis: sensitivity 73.3%, specificity 98%; P-ANCA for microscopic polyangiitis: sensitivity 86.7%, specificity 98%). The sensitivities of PR3-ANCA and MPO-ANCA ELISA kits were increased by lowering the cut off values. This reduced specificity but increased overall diagnostic performance. CONCLUSIONS The low sensitivity of some commercial kits reflects the high cut off levels recommended rather than methodological problems with the assays. Comparative analyses using sera from well characterised patients may help identify optimum cut off levels of commercial ANCA ELISA tests, resulting in better comparability of results among assays from different manufacturers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EXTENDED REPORT Variations in performance characteristics of commercial enzyme immunoassay kits for detection of antineutrophil cytoplasmic antibodies: what is the optimal cut off?

Background: Previous studies have shown considerable variation in diagnostic performance of enzyme linked immunosorbent assays (ELISAs) for measuring antineutrophil cytoplasmic antibodies (ANCA) specific for proteinase 3 (PR3) and myeloperoxidase (MPO). Objective: To analyse the performance characteristics of different commercially available direct ANCA ELISA kits. Methods: ELISA kits for detec...

متن کامل

Auto-antibodies in Patients with Inflammatory Bowel Disease Unclassified

Background: Inflammatory bowel disease unclassified (IBDU) is considered to be an aberrant immune response with loss of tolerance to many antigens. Objective: This paper tries to address whether there is any value to test for auto-antibodies in such patients. Methods: 60 patients with inflammatory bowel disease unclassified participated in the study. Auto-antibodies to nuclear antigen, intestin...

متن کامل

Adaptation of an indirect enzyme-linked immunosorbent assay by purified gp51SU for detection of antibodies to bovine leukemia virus

The objective of this study was to compare an indirect ELISA, based on a purified 60 kDa envelope glycoprotein (gp51SU), with a Pourquire indirect ELISA for the detection of antibodies to the bovine leukemia virus. For conducting this research, 340 serum samples were collected from two different breeds of cows (Sarabi and Holestin) in different herds. Commercial ELISA revealed positive results ...

متن کامل

Antineutrophil Cytoplasmic Antibodies in Patients with Pulmonary Tuberculosis

Background: Mycobacterium tuberculosis is a major cause of mortality and morbidity worldwide. Infection with this bacterium is known to induce the development of autoantibodies of which a few are also known to be diagnostic markers for some other diseases. Antineutrophil Cytoplasmic Antibodies (ANCA's) are among those autoantibodies used in clinical setting for diagnosing systemic vasculitic sy...

متن کامل

ANTINEUTROPHIL CYTOPLASMIC AUTOANTIBODI ES IN RHEUMATOID ARTHRITIS

Antineutrophil cytoplasmic autoantibodies (ANCA) were detected in patients with autoimmune and vascular diseases such as Wegener's granulomatosis, polyarteritis nodosa and systemic lupus erythematosus. Indirect immunofluorescence (IIF) technique was employed to detect these autoantibodies. By this method, two general patterns of ANCA were seen: a cytoplasmic (cANCA) and a perinuclear form ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the rheumatic diseases

دوره 64 12  شماره 

صفحات  -

تاریخ انتشار 2005