Long-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite
نویسندگان
چکیده
PURPOSE The evaluation of the safety, efficacy, and long-term stability of LASIK procedures utilizing novel platform comprising a femtosecond and excimer laser and multiple networked diagnostics. SETTING Private clinical ophthalmology practice. PATIENTS AND METHODS In consecutive cases of myopic LASIK procedure with a novel refractive platform (FS200 Femtosecond and EX500 Excimer Laser), 190 eyes (from 109 different patients) were evaluated pre- and postoperatively for the following parameters: refractive error, best corrected distance visual acuity, uncorrected distance visual acuity, topography (Placido-disc based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. RESULTS The change from pre- to postoperative mean refractive error was from -5.29 ± 2.39 diopters (D) (range -8.0 to -0.50 D) to -0.27 ± 0.09 D at the 3-month visit, -0.27 ± 0.10 D at the 6-month visit, and -0.39 ± 0.08 D at the 1-year visit. The change from pre- to postoperative refractive astigmatism was -1.07 ± 0.91 D (range -4.25 to 0 D) to -0.14 ± 0.04 D at 3 months, -0.15 ± 0.04 at 6 months, and -0.16 ± 0.04 at the 1-year visit. The proportion of the eyes with postoperative astigmatism within 0.5 D ranged between 95.6% and 99%. The proportion of eyes achieving uncorrected distance visual acuity of 1.0 (decimal) was 93.0%. CONCLUSION The myopic LASIK clinical results with the FS200 Femtosecond Laser and EX500 Excimer Laser showed outstanding efficacy, great safety, and long-term stability.
منابع مشابه
Predictability of Corneal Flap Thickness in LASIK Using the WaveLight FS200 Femtosecond Laser
250 of 250 words) Purpose: To compare the intended versus resultant thickness of laser in situ keratomileusis (LASIK) flaps created with a new femtosecond laser (WaveLight FS200 Femtosecond Laser, WaveLight GmbH, Alcon Laboratories) and to report refractive outcomes at 3 months posttreatment. Setting: Wellington Eye Clinic, Dublin, Ireland Design: Retrospective consecutive case series Methods: ...
متن کاملAssessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction
INTRODUCTION Laser vision correction for hyperopia is challenging. The purpose of the study was to assess the refractive outcomes of femtosecond-assisted laser in situ keratomileusis (LASIK) for hyperopic correction using wavefront-optimized ablation profiles. METHODS This retrospective case series study included 20 Egyptian patients (40 eyes) with hyperopia or hyperopic astigmatism with a me...
متن کاملAccuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK
PURPOSE To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). MATERIALS AND METHODS This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a des...
متن کاملDigital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique
BACKGROUND The purpose of this study was to determine flap parameter accuracy, extent of the opaque bubble layer, and incidence of skip lines in femtosecond laser-assisted stromal in situ keratomileusis (LASIK) using the WaveLight(®) FS200 laser and optoelectronic clinical measurements. METHODS Images from 101 flaps were automatically recorded during consecutive routine LASIK procedures perfo...
متن کاملHigh incidence of rainbow glare after femtosecond laser assisted-LASIK using the upgraded FS200 femtosecond laser
BACKGROUND To compare the incidence of rainbow glare (RG) after femtosecond laser assisted-LASIK (FS-LASIK) using the upgraded FS200 femtosecond laser with different flap cut parameter settings. METHODS A consecutive series of 129 patients (255 eyes) who underwent FS-LASIK for correcting myopia and/or astigmatism using upgraded WaveLight FS200 femtosecond laser with the original settings was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -