PATHFAST, a novel chemiluminescent enzyme immunoassay for measuring estradiol in equine whole blood and serum
نویسندگان
چکیده
A novel chemiluminescent enzyme immunoassay system, PATHFAST, for the measurement of estradiol in horses was evaluated. The concentrations of estradiol in the whole blood and serum of mares were measured using PATHFAST and the estradiol concentrations measured by PATHFAST were compared with those measured by a time-resolved fluoro-immunoassay (FIA). To monitor physiological changes, serum estradiol concentrations in mares were measured using PATHFAST throughout the gestation period. The serum estradiol concentrations correlated highly with those in whole blood samples. The serum concentrations of estradiol measured by PATHFAST also correlated well with FIA. Circulating estradiol increased during mid-gestation and high levels of serum estradiol were maintained in late gestation, followed by an abrupt decline to term. These results demonstrate the utility of PATHFAST in equine clinics as an accurate diagnostic tool for the rapid assay of estradiol within 26 min using unextracted whole blood.
منابع مشابه
Evaluation of the PATHFAST Chemiluminescent Enzyme Immunoassay for Measuring Progesterone in Whole Blood and Serum of Mares
Evaluation of a new chemiluminescent enzyme immunoassay, the PATHFAST assay system (PATHFAST), for measurement of circulating progesterone in mares was performed. Five mares at the mid-luteal stage were administrated a single i.m. injection of prostaglandin F2α analog (PGF2α; cloprostenol 250 μg/ml), and then blood samples were collected from the jugular vein at 0, 15, 30 and 45 min, at one-hou...
متن کاملDevelopment of a point-of-care assay system for measurement of presepsin (sCD14-ST).
BACKGROUND The soluble CD14 subtype (sCD14-ST: renamed as presepsin) is a novel soluble CD14 molecule that is useful for diagnosing sepsis because sCD14-ST levels increase specifically in sepsis patients. METHODS A fully automated PATHFAST® Presepsin assay system based on a chemiluminescent enzyme immunoassay was developed for detecting presepsin in human whole blood. RESULTS The limit of b...
متن کاملA rapid and quantitative D-Dimer assay in whole blood and plasma on the point-of-care PATHFAST analyzer.
The objective of this study was to evaluate the accuracy indices of the new rapid and quantitative PATHFAST D-Dimer assay in patients with clinically suspected deep-vein thrombosis (DVT). Eighty two consecutive patients (34% DVT, 66% non-DVT) with suspected DVT of a lower limb were tested with the D-Dimer assay with a PATHFAST analyzer. The diagnostic value of the PATHFAST D-Dimer assay (which ...
متن کاملEvaluation of the chemiluminescent enzyme immunoassay system for the measurement of testosterone in the serum and whole blood of stallions
Testosterone (T) concentration is a useful indicator of reproductive function in male animals. However, T concentration is not usually measured in veterinary clinics, partly due to the unavailability of reliable and rapid assays for animal samples. In this study, a rapid chemiluminescent enzyme immunoassay system (CLEIA system) that was developed for the measurement of T concentration in humans...
متن کاملRapid and sensitive chemiluminescent enzyme immunoassay for measuring tumor markers.
We developed a chemiluminescent enzyme immunoassay (CLEIA) to quantify such tumor markers as carcinoembryonic antigen (CEA), alpha-fetoprotein (AFP), CA19-9, and CA125. We used a novel chemiluminescent substrate, a derivative of 1,2-dioxetane phosphate (AMPPD), to measure alkaline phosphatase as a labeling enzyme to Fab' fragments of antibody. Regardless of the solid phase, i.e., polystyrene be...