Suitability of Filofocon A and PMMA for experimental models in excimer laser ablation refractive surgery.

نویسندگان

  • Carlos Dorronsoro
  • Jan Siegel
  • Laura Remon
  • Susana Marcos
چکیده

Experimental corneal models in plastic (in PMMA, and more recently in Filofocon A, a contact lens material) have been proposed recently to overcome some of the limitations of the theoretical approaches aiming at improving the predictability of corneal reshaping by laser ablation. These models have also been proposed for accurate assessment of corneal laser ablation patterns. In this study Filofocon A and PMMA optical and ablation properties were studied using an experimental excimer laser set-up. The effective absorption coefficient and the ablation thresholds of these materials were obtained as a function of the number of pulses. Both materials follow a Beer-Lambert law in the range of fluences used in refractive surgery, and the number of incubation pulses is less than 4 (PMMA) and 2 (Filofocon A) above 140 mJ/cm2. We found that above 40 pulses for Filofocon A and 70 pulses for PMMA, ablation threshold and effective absorption coefficients can be considered constant (F th = 90 mJ/cm2 and alpha eff = 36000 cm(-1), for Filofocon A, and F th = 67 mJ/cm2 and alpha eff = 52000 cm(-1) for PMMA, respectively). The absence of ablation artifacts (central islands), a lower number of incubation pulses, a lower pulse-number dependence of the ablation threshold, and a good correspondence between alpha eff and the absorption coefficient alpha estimated from spectroscopic measurements make Filofocon A a more appropriate material than PMMA for experimental models in refractive surgery and for calibration of clinical lasers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of optimized ablation patterns for laser refractive surgery.

A new experimental model based on plastic (Filofocon A) artificial eyes was used to study the ablation profiles and the outcomes of three state-of-the-art refractive surgery excimer lasers provided with narrow-beam flying spot and optimized algorithms (Ladarvision 4000, Alcon; Technolas 217 Z100, Bausch and Lomb; Allegretto wave Eye-Q, Wavelight). The 3-D ablation patterns produced by myopic la...

متن کامل

Surface temperature change of pmma plateS in refractive Surgery performed with two typeS of modern excimer laSerS

Introduction. the conditions in the operating room can have an influence on the postoperative results of the refractive surgery performed with excimer lasers. Aim. the aim of this study was to examine the relationship of the temperature of pmma plates (polymethylmethacrylate), environmental conditions and the energy load caused by the laser impulses during refractive surgery procedure. Material...

متن کامل

Effect of air-flow on the evaluation of refractive surgery ablation patterns.

An Allegretto Eye-Q laser platform (Wavelight GmbH, Erlangen, Germany) was used to study the effect of air-flow speed on the ablation of artificial polymer corneas used for testing refractive surgery patterns. Flat samples of two materials (PMMA and Filofocon A) were ablated at four different air flow conditions. The shape and profile of the ablated surfaces were measured with a precise non-con...

متن کامل

Smoothness of ablation on polymethylmethacrylate plates with four scanning excimer lasers.

PURPOSE To perform a quantitative evaluation of smoothness of ablation on polymethylmethacrylate (PMMA) using four scanning excimer lasers available commercially for photorefractive surgery. METHODS Ablations were done on PMMA plates with dimensions 100 x 50 x 1 mm. Four scanning excimer lasers were used, two with flying spot technology (Zeiss-Meditec MEL-70, and a Russian-made unit, Microsca...

متن کامل

Experiments on PMMA models to predict the impact of corneal refractive surgery on corneal shape.

Flat and spherical PMMA surfaces were ablated with a standard refractive surgery laser system. The ratio of profiles on flat to spherical PMMA surfaces was used to estimate experimentally the radial change in ablation efficiency for PMMA and cornea. Changes in ablation efficiency accounted for most of the asphericity increase found clinically, using the same laser system. This protocol is usefu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 16 25  شماره 

صفحات  -

تاریخ انتشار 2008