Clonidine increases the sweating threshold, but does not reduce the gain of sweating.

نویسندگان

  • L Delaunay
  • T Herail
  • D I Sessler
  • A Lienhart
  • F Bonnet
چکیده

We tested the hypothesis that clonidine produces a dose-dependent increase in the sweating threshold but does not reduce the gain of sweating. Six healthy male volunteers were evaluated, each on three separate days in random order. In one, saline was administered; in another, a 2-micrograms/kg bolus of clonidine was followed by an infusion at 2 micrograms.kg-1.h-1, and on a third day, a 4-micrograms/kg bolus was followed by an infusion at 4 micrograms.kg-1.h-1. Core temperature was measured at the tympanic membrane and mean skin temperature was determined from four sites. A chest sweating rate of 40 g.m-2.h-1 was considered significant. The core temperature triggering sweating, adjusted to a designated mean skin temperature of 34 degrees C, identified the threshold for this response. Gain was defined by the adjusted core temperature increase required to augment sweating from 100 to 300 g.m-2.h-1. degree C-1. Plasma clonidine concentrations were 0.8 +/- 0.1 and 1.6 +/- 0.2 ng/mL on the small- and large-dose days, respectively. Clonidine administration increased the sweating threshold approximately 0.4 degree C (P < 0.05), but the increase was comparable at each dose. The gain of sweating was approximately 0.2 degree C and was not influenced by clonidine administration. The thermoregulatory effects of clonidine thus resemble those of volatile anesthetics, opioids, and propofol. These data suggest that the antishivering effect of clonidine results from central thermoregulatory inhibition rather than a specific peripheral action on thermogenic muscular activity. Unlike other sedatives and anesthetics, the concentration-dependence of clonidine demonstrates a ceiling beyond which the administration of an additional drug fails to enhance the effect, suggesting that the thermoregulatory effect of clonidine may be limited, even at high plasma concentrations. The gain of sweating was well preserved indicating that this response remains effective in the presence of sedatives and anesthetics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clonidine decreases vasoconstriction and shivering thresholds, without affecting the sweating threshold.

PURPOSE This study was conducted to test the hypothesis that clonidine produces a dose-dependent increase in the sweating threshold and dose-dependent decreases in vasoconstriction and shivering thresholds. METHODS Six healthy subjects (two female) were studied on four days after taking clonidine in oral doses of either 0 (control), 3, 6 or 9 micrograms.kg-1. The order followed a balanced des...

متن کامل

Estrogen raises the sweating threshold in postmenopausal women with hot flashes.

OBJECTIVE To determine if estrogen ameliorates hot flashes by raising the core body temperature sweating threshold, by reducing core body temperature fluctuations, and/or by reducing sympathetic activation (as measured by plasma 3-methoxy-4-hydroxyphenylglycol). DESIGN Laboratory physiological study. SETTING University medical center. PATIENT(S) Twenty-four healthy postmenopausal women re...

متن کامل

Glycopyrrolate-induced craniofacial compensatory hyperhidrosis successfully treated with oxybutynin: report of a novel adverse effect and subsequent successful treatment.

Hyperhidrosis, or abnormally increased sweating, is a condition that may have a primary or secondary cause. Usually medication- induced secondary hyperhidrosis manifests with generalized, rather than focal sweating. We report a 32-year-old woman with a history of palmoplantar hyperhidrosis for 15 years who presented for treatment and was prescribed oral glycopyrrolate. One month later, the palm...

متن کامل

A simple and valid method to determine thermoregulatory sweating threshold and sensitivity.

Sweating threshold temperature and sweating sensitivity responses are measured to evaluate thermoregulatory control. However, analytic approaches vary, and no standardized methodology has been validated. This study validated a simple and standardized method, segmented linear regression (SReg), for determination of sweating threshold temperature and sensitivity. Archived data were extracted for ...

متن کامل

Sex differences in postsynaptic sweating and cutaneous vasodilation.

The current study aimed to determine whether a peripheral modulation of sweating contributes to the lower sudomotor thermosensitivity previously observed in females during exercise. We examined dose-response relationships in 12 males and 12 females to incremental doses of acetylcholine (ACh) and methylcholine (MCh) for sweating (ventilated capsule), as well as to ACh and sodium nitroprusside (S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 1996