Computer aided vertebral visualization and analysis: a methodology using the sand rat, a small animal model of disc degeneration

نویسندگان

  • Christy Wilson
  • Darien Brown
  • Kayvan Najarian
  • Edward N Hanley
  • Helen E Gruber
چکیده

BACKGROUND The purpose of this study is to present an automated system that analyzes digitized x-ray images of small animal spines identifying the effects of disc degeneration. The age-related disc and spine degeneration that occurs in the sand rat (Psammomys obesus) has previously been documented radiologically; selected representative radiographs with age-related changes were used here to develop computer-assisted vertebral visualization/analysis techniques. Techniques presented here have the potential to produce quantitative algorithms that create more accurate and informative measurements in a time efficient manner. METHODS Signal and image processing techniques were applied to digitized spine x-ray images the spine was segmented, and orientation and curvature determined. The image was segmented based on orientation changes of the spine; edge detection was performed to define vertebral boundaries. Once vertebrae were identified, a number of measures were introduced and calculated to retrieve information on the vertebral separation/orientation and sclerosis. RESULTS A method is described which produces computer-generated quantitative measurements of vertebrae and disc spaces. Six sand rat spine radiographs illustrate applications of this technique. Results showed that this method can successfully automate calculation and analysis of vertebral length, vertebral spacing, vertebral angle, and can score sclerosis. Techniques also provide quantitative means to explore the relation between age and vertebral shape. CONCLUSIONS This method provides a computationally efficient system to analyze spinal changes during aging. Techniques can be used to automate the quantitative processing of vertebral radiographic images and may be applicable to human and other animal radiologic models of the aging/degenerating spine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new small animal model for the study of spine fusion in the sand rat: pilot studies.

Spine fusion is used to treat traumatic or degenerative lumbar instability in the cervical or lumbar spine. Although degenerative radiological changes in discs adjacent to a fusion have been well-recognized, histopathological changes in adjacent discs have not been studied and are poorly understood. An economical small animal model for lumbar fusion would be a useful research tool. Study object...

متن کامل

Degenerative Disc Disease: A Review of Cell Technologies and Stem Cell Therapy

Background & Aim: Low back pain is broadly documented as one of the most widespread pathologies in the advanced domain. Although the reasons of low back pain are uncountable, it has been meaningfully related to intervertebral disc degeneration. Present therapies for Intervertebral Disc (IVD) degeneration such as physical therapy and spinal fusion reduce symptoms' severity, but do not treat the ...

متن کامل

Bridging Small-Gap Peripheral Nerve Defect Using Silicone Rubber Chamber in the Rat Sciatic Nerve Transection Model

  Despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. Present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. Fifty- four male Wistar rats were divided into three experimental groups (n = 1...

متن کامل

Non-invasive quantification of age-related changes in the vertebral endplate in rats using in vivo DCE-MRI

BACKGROUND Small animal models that can mimic degenerative disc disease (DDD) are commonly used to examine DDD progression. However, assessments such as histological studies and macroscopic measurements do not allow for longitudinal studies because they can only be completed after the animal is sacrificed. Dynamic contrast-enhanced MRI (DCE-MRI) may provide a reliable, non-invasive in vivo meth...

متن کامل

A Methodology for Product Performance Analysis under Effects of Multi-Physical Phenomena

Due to the development of science and technology, the computer has become a useful tool for supporting engineering activities in product design. Many computer aided tools such as CAD/CAM, product data management (PDM), product life cycle assessment (PLA), etc., have been popularly used in industry for reducing product development lead-time and increasing total product quality. However, the nume...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Musculoskeletal Disorders

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2003