A Simulation for Predicting the Refrigerant Flow Characteristics Including Metastable Region in Non-Adiabatic Capillary Tubes

نویسندگان

  • Kidong Son
  • Jihwan Jeong
  • Lyunsu Kim
  • Sang-Goo Park
  • Ji Hwan Jeong
  • Lyun-su Kim
چکیده

The capillary tube/suction line heat exchanger (SLHX) is widely used in small refrigeration systems. The refrigerant flowing in the SLHX experiences frictional and accelerational head losses, flashing, and heat transfer simultaneously. The simulation of refrigerant flow through SLHX is important since this will help engineers analyze and optimize the SLHX incorporated in a refrigeration system. The present SLHX model is based on conservation equations of mass, momentum and energy. Also a meta-stable model is included. All these equations are solved simultaneously. In this paper, HFC-134a refrigerant flow through a non-adiabatic capillary tube is simulated. The simulation results are discussed but not validated against experimental measurements yet.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Analysis of Capillary Tubes for CFC-12 and HFC-134a

This work presents experimental data for capillary tubes of the type commonly used as expansion devices in domestic appliances, employing CFC-12 and HFC-134a as working fluids. Capillary tubes of 0. 7, 0.8 and 1.0 millimeter internal diameter with lengths of 3 and 2 meters were tested. Condensing pressures of 18, 14, 11 and 9 bar, and subcooling ranging from 14 to 2 oc were chosen as the operat...

متن کامل

Influence Of Oil On Flow Characteristics Through Capillary Tube In Refrigeration Cycle

A capillary tube is widely used as an expansion device for small refrigeration cycles. Recently, immiscible oil is sometimes used in the refrigeration cycle to improve severe lubricating conditions and to prevent blockage of the capillary tube caused by the hydrolysis of ester oil. This paper discusses the influence of mixing of the immiscible oil with the refrigerant on the flow characteristic...

متن کامل

Rating Charts of R-22 Alternatives Flow through Adiabatic Capillary Tubes

Drop-in of R-22 alternatives in refrigeration and air conditioning systems requires a redesign of system components to improve system performance and reliability with the alternative refrigerants. The present paper aims at design adiabatic capillary tubes for R-22 alternatives such as R-417A, R-422D and R-438A. A theoretical model has been developed and validated with the available experimental...

متن کامل

Capillary Effects on Surface Enhancement in a Non-Homogeneous Fibrous Porous Medium

The evaluation of a free fluid surface in a porous medium has several mathematical applications that are important in industries using molds, particularly in the fluid injection process. The vacuum-assisted resin transfer molding (VARTM) process is a promising technology in the primary composite industry. An accurate computational simulation of the VARTM process would be a cost-effective tool i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014