Development of a Rapid and Simple Method for Detection of Protein Contaminants in Carmine
نویسندگان
چکیده
Protein contaminants in carmine can cause dyspnea and anaphylactic reactions in users and consumers of products containing this pigment. The method generally used for detection of proteins in carmine has low reproducibility and is time-consuming. In this study, a rapid, simple, and highly reproducible method was developed for the detection of protein contaminants in carmine. This method incorporates acidic protein denaturation conditions and ultrafiltration. To prevent protein aggregation, sodium dodecyl sulfate containing gel electrophoresis running buffer was used for dispersing the carmine before filtration. An ultrafiltration device was used to separate the protein contaminants from carminic acid in the carmine solution. Two ultrafiltration devices were compared, and a cylindrical device containing a modified polyethersulfone membrane gave the best results. The method had high reproducibility.
منابع مشابه
A Simple and Rapid Leaf Genomic DNA Extraction Method for Polymerase Chain Reaction Analysis
In plants, secondary metabolites and polysaccharides interfere with genomic isolation procedures and downstream reactions such as restriction enzyme analysis and gene amplification. The removal of such contaminants needs complicated and time-consuming protocols. In this study, a simple, rapid and efficient method for leaf DNA extraction was optimized. This method use small amount of plant mater...
متن کاملSensitive and spectrophotometric methods for the determination of Azathioprine in tablets using indigo carmine and methyl orange
A simple, economical, precise and fast visible spectrophotometric method has been developed for the determination of Azathioprine in tablet dosage form. Developed method is based on the formation of extractable colored complex of drug with colouring agent Indigo Carmine and Methyl orange. A wavelength maximum was found to be 683.7 nm and 566 nm. The concentration range of 15-50 μg mL-1 with of ...
متن کاملDevelopment of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat
A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...
متن کاملDevelopment of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat
A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015