Variability in Observer Performance Between Faculty Members and Residents Using Breast Imaging Reporting and Data System (BI-RADS)-Ultrasound, Fifth Edition (2013)

نویسندگان

  • Youn Joo Lee
  • So Young Choi
  • Kyu Sun Kim
  • Po Song Yang
چکیده

BACKGROUND Ultrasonography (US) is a useful tool for breast imaging, yet is highly operator-dependent. OBJECTIVES We evaluated inter-observer variability and performance discrepancies between faculty members and radiology residents when describing breast lesions, by the fifth edition of breast imaging reporting and data system (BI-RADS)-US lexicon, and then attempted to identify whether inter-observer variability could be improved after one education session. PATIENTS AND METHODS In total, 50 malignant lesions and 70 benign lesions were considered in our retrospective study. Two faculty members, two senior residents, and two junior residents separately assessed the US images. After the first assessment, the readers received one education session, and then reassessed the images in a random order. Inter-observer variability was measured using the kappa coefficient (κ). Performance discrepancy was evaluated by receiver operating characteristic (ROC) curves. RESULTS For the faculty members, fair-to-good agreement was obtained in all descriptors and final assessment, while for residents, poor-to-moderate agreement was obtained. The areas under the ROC curves were 0.78 for the faculty members, 0.59 for the senior residents, and 0.52 for the junior residents, respectively. Diagnostic performance was significantly higher in the faculty members than the senior and junior residents (P = 0.0001 and < 0.0001, respectively). After one education session, the agreement in the final assessment was one level higher in the faculty members and senior residents, yet in the senior residents, the degree of agreement was still only fair. Moreover, in the junior residents, there was no improvement. CONCLUSION Investigative assessment of breast US by residents is inadvisable. We recommend continued professional resident training to improve the degree of agreement and performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the fifth edition BI-RADS ultrasound lexicon with comparison of fourth and fifth edition diagnostic performance using video clips

PURPOSE The aim of this study was to evaluate the positive predictive value (PPV) and the diagnostic performance of the ultrasonographic descriptors in the fifth edition of BI-RADS, comparing with the fourth edition using video clips. METHODS From September 2013 to July 2014, 80 breast masses in 74 women (mean age, 47.5±10.7 years) from five institutions of the Korean Society of Breast Imagin...

متن کامل

Practical and illustrated summary of updated BI-RADS for ultrasonography

The American College of Radiology released the fifth edition of the Breast Imaging-Reporting and Data System (BI-RADS) in 2014 (copyright 2013), which includes the expanded second edition of the ultrasound BI-RADS lexicon. This review provides a practical summary of the updated lexicon, including selective illustrations with original clinical images, a discussion of overarching concepts, and ex...

متن کامل

Relationship between BI-RADS 4 Ultrasound Index and Pathological Findings and Clinical Outcomes in Breast Lesions

Introduction: breast cancer is listed as the most common type of cancer in women and many patients suffer from this disease worldwide. However, the timely diagnosis of the condition can lower the rate of mortality and morbidity. Breast imaging-reporting and data system (BI-RADS) is a noninvasive scoring system. The aim of our study was to assess the BI-RADS for patients and evaluate the corresp...

متن کامل

BI-RADS 3: Current and Future Use of Probably Benign

Purpose of Review Probably benign (BI-RADS 3) causes confusion for interpreting physicians and referring physicians and can induce significant patient anxiety. The best uses and evidence for using this assessment category in mammography, breast ultrasound, and breast MRI will be reviewed; the reader will have a better understanding of how and when to use BI-RADS 3. Recent Findings Interobserv...

متن کامل

Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions.

BACKGROUND Elastographpy is a newly developed noninvasive imaging technique that uses ultrasound (US) to evaluate tissue stiffness. The interpretation of the same elastographic images may be variable according to reviewers. Because breast lesions are usually reported according to American College of Radiology Breast Imaging and Data System (ACR BI-RADS) lexicons and final category, we tried to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2016