Estimation of 99mTc-MAG3 clearance by single-sample methods and camera-based methods.

نویسندگان

  • Y Inoue
  • K Yoshikawa
  • I Yokoyama
  • K Ohtomo
چکیده

We compared single-sample methods, proposed by Russell et al. and Bubeck et al., and camera-based methods in calculating 99mTc-MAG3 clearance, and determined camera-based methods that provide estimates comparable to those measured by the Russell method. Twenty-one patients underwent 99mTc-MAG3 renal scintigraphy, and clearance was measured by the Russell method and Bubeck method. Various renogram parameters were determined based on the slope of the renogram and area under the renogram, and correlated with the clearance measured by the Russell method. Camera-based clearance was calculated with the obtained regression equations and with equations determined previously using the Bubeck method as a standard. The Bubeck method provided lower measures than the Russell method in high renal function. Clearance measured by the Russell method was well correlated with renogram parameters, and clearance calculated with the obtained regression equation was comparable to that measured by the Russell method. When camera-based clearance was predicted with the previous equation, it was lower than the result obtained by the Russell method in high function. In conclusion, there are systematic differences in 99mTc-MAG3 clearance calculated by different methods. The camera-based methods obtained in this study appear to facilitate comparison of results obtained by the Russell method and camera-based method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

Prediction of renal transplant survival from early postoperative radioisotope studies.

UNLABELLED It has been routine at the University of Alabama Medical Center to obtain a radionuclide renal function study immediately after transplantation (usually within 3 d) that includes estimation of effective renal plasma flow (ERPF) from a single plasma sample in addition to imaging. We present here the correlation between baseline measurements and the 1-y graft survival. METHODS Two co...

متن کامل

Synthesis, formulation and quality control of 99mTc-MAG3, as a renal tubular 99mTc-radiopharmaceutical kit [Persian]

Radionuclidic techniques may provide assessment of glomerular filtration rate (GFR) effective renal plasma flow (ERPF) or individual renal function. Several agents were available for determination of these parameters such as ¹³¹I-OIH (O-iodohippurate) and different derivatives of DADS (Diamidodisulfur). OIH has the disadvantage of imparting a relatively high absorbed radiation dose to the...

متن کامل

A Bayesian 3-compartment model for 99mTc-MAG3 clearance.

UNLABELLED Because recent reports have questioned the traditional 2-compartment model for calculating tracer clearance after a single intravenous injection, a 3-compartment model was evaluated in this study. METHODS Bayesian statistics were used, which facilitated curve fitting by treating all subjects simultaneously. (99m)Tc-Mercaptoacetyltriglycine clearance data from 154 adults and 109 chi...

متن کامل

Evaluation of Renal Function: A Comparison Between Camera-Based Tc-99m MAG3 and 24-Hour Creatinine Clearances

OBJECTIVE: The 24-hour creatinine clearance is the standard clinical technique to measure renal function; however, this measurement is cumbersome and inconvenient for patients. We hypothesized that a camera-based Tc-99m mercaptoacetyltriglycine (MAG3) clearance obtained simultaneously with a standard MAG3 scan would correlate well with the 24-hour creatinine clearance and could serve as a simpl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 2000