Thermal stability of premature infants during routine care under radiant warmers.

نویسندگان

  • J H Seguin
  • R Vieth
چکیده

The body temperatures of infants weighing less than 1500 g under radiant warmers during routine care were documented in the first week of life. Ten infants (median gestational age 28 weeks, median birthweight 913 g) were studied. During 30 nursing interventions (mean 9.2 minutes) mean oesophageal and foot temperature changed 0 degrees C and -0.11 degrees C, respectively. A radiant warmer may limit heat loss during interventions because of easy access and rapid radiant warmer responsiveness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit

Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe fo...

متن کامل

Pediatric Pulmonology 38:50–54 (2004) Inspired Gas Temperature in Ventilated Neonates

The warming and humidification of inspired gases for ventilated neonates are routine. There are no data on the temperature of the gasat the airway opening in ventilated neonates. Is the inspired gas temperature at the airway opening, as expected and set on the humidifier, around 378C?We aimed to measure temperature at the airway opening and compare this with the circuit temperature. This was an...

متن کامل

Thermal Blanket to Improve Thermoregulation in Preterm Infants: A Randomized Controlled Trial.

OBJECTIVE To determine the effectiveness of temperature-controlled thermal blanket as additional thermoprotection. DESIGN Randomized controlled prospective study. SETTING Single-center tertiary neonatal unit. PATIENTS Inborn very low-birth-weight (< 1,500 g) infants. INTERVENTIONS Infants were prospectively assigned to thermal blanket group or control at 1:1 ratio. Additional to radiant...

متن کامل

Investigation of oxygenation in premature infants under mechanical ventilation in supine position compare to side lying

Abstract Introduction: Changing position is an important aspect within nursing care. Prone positioning amongst premature infants could improve their oxygenation compared to supine position. Side lying position leads to developed support between premature infants, however there is few studies about effects of this position on premature infants 'oxygenation. Objective: This study was conduc...

متن کامل

A laminar flow unit for the care of critically ill newborn infants

INTRODUCTION Medical and nursing care of newborns is predicated on the delicate control and balance of several vital parameters. Closed incubators and open radiant warmers are the most widely used devices for the care of neonates in intensive care; however, several well-known limitations of these devises have not been resolved. The use of laminar flow is widely used in many fields of medicine, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 74 2  شماره 

صفحات  -

تاریخ انتشار 1996