3-T imaging of the cochlear nerve and labyrinth in cochlear-implant candidates: 3D fast recovery fast spin-echo versus 3D constructive interference in the steady state techniques.

نویسندگان

  • John I Lane
  • Heidi Ward
  • Robert J Witte
  • Matt A Bernstein
  • Colin L W Driscoll
چکیده

BACKGROUND AND PURPOSE High-resolution imaging of the internal auditory canal and labyrinth at 1.5 T is often performed by using three-dimensional (3D) fast spin-echo or T2* techniques. We evaluated both techniques at 3 T in the preoperative assessment of patients being considered for cochlear implants. METHODS Sagittal 3D fast recovery fast spin-echo (FRFSE) and 3D constructive interference in the steady state (CISS) images were acquired in eight patients at 3.0 T by using dual surface coils. Contrast-to-noise ratios (CNRs) for the intracanalicular nerve and CSF were measured in the internal auditory canal. Two neuroradiologists reviewed the images to determine whether the techniques provided images of diagnostic quality. RESULTS CNRs for 3D CISS were twice those obtained with 3D FRFSE. Both techniques provided images of diagnostic quality, though spurious signal intensity loss at the apex of the superior semicircular canals was encountered on 3D FRFSE images in four of eight patients. CONCLUSION Both 3D FRFSE and 3D CISS provide high-resolution images of the internal auditory canal and labyrinth at 3.0 T. We predict that the superior CNRs obtained with 3D CISS will prove advantageous as we move to smaller fields of view at higher field strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Aplasia and hypoplasia of the vestibulocochlear nerve: diagnosis with MR imaging.

PURPOSE To introduce aplasia or hypoplasia of the vestibulocochlear nerve (VCN) as a possible cause of hearing loss and to identify the magnetic resonance (MR) imaging characteristics of this entity. MATERIALS AND METHODS In seven patients with congenital deafness or unexplained sensorineural hearing loss, MR imaging enabled diagnosis of aplasia or hypoplasia of the VCN. Axial (0.7-mm) three-...

متن کامل

A 46-Year-Old Woman with Unilateral Hearing Loss: A Recent Diagnosis of a Birth Condition

Cochlear nerve (CN) aplasia refers to the absence of a visible CN on oblique sagittal magnetic resonance images of the lateral aspect of the inner auditory canal (IAC). Magnetic resonance (MR) is the preferred technique in patients with sensorineural hearing loss and/or vertigo; however, computed tomography (CT) is used to evaluate the IAC or facial nerve canal. Three types of aplasia or hypopl...

متن کامل

Fast recovery 3D fast spin-echo MR imaging of the inner ear at 3 T.

High-resolution MR imaging of the inner ear with a heavily T2-weighted 3D fast spin-echo sequence has been performed successfully at 1.5 T. However, at 3 T, the longer T1 time of CSF necessitates a longer TR, resulting in significantly prolonged imaging times. In this study, the fast recovery 3D fast spin-echo sequence, which permits the TR to be reduced while maintaining T2 contrast, was optim...

متن کامل

MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences.

BACKGROUND AND PURPOSE MR cisternography has been used as the noninvasive screening tool of the cerebellopontine angle. The purpose of this study was to directly compare two currently dominant types of sequences for heavily T2-weighted MR cisternography. METHODS Three-dimensional fast asymmetric spin-echo (3D-FASE) sequences, which are 3D half-Fourier rapid acquisition with relaxation enhance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2004