Comparison of CTAC and prone imaging for the detection of coronary artery disease using CZT SPECT

نویسندگان

  • Shimpei Ito
  • Akihiro Endo
  • Taiji Okada
  • Taku Nakamura
  • Takashi Sugamori
  • Nobuyuki Takahashi
  • Hiroyuki Yoshitomi
  • Kazuaki Tanabe
چکیده

BACKGROUND Cadmium-zinc-telluride (CZT) cameras have improved the evaluation of patients with chest pain. However, inferior/inferolateral attenuation artifacts similar to those seen with conventional Anger cameras persist. We added prone acquisitions and CT attenuation correction (CTAC) to the standard supine image acquisition and analyzed the resulting examinations. METHODS AND RESULTS Seventy-two patients referred for invasive coronary angiography (CAG), and who also underwent rest/stress myocardial perfusion imaging (MPI) on a CZT camera in the supine and prone positions plus CTAC imaging, to examine known or suspected CAD between April 2013 and March 2014 were included. A sixteen-slice CT scan acquired on a SPECT/CT scanner between rest and stress imaging provided data for iterative reconstruction. Sensitivity, specificity, accuracy, and positive and negative likelihood ratios (LRs) were calculated to compare MPI with CAG on a per-patient basis. Per-patient sensitivity, specificity, and accuracy of supine images to predict coronary abnormalities on CAG were 35% [95% confidence interval (CI) 19-52], 86% (95% CI 80-92), and 74% (95% CI 66-82); those of prone imaging were 65% (95% CI 45-81), 82% (95% CI 76-87), and 78% (95% CI 68-85); and those of CTAC were 59% (95% CI 41-71), 93% (95% CI 87-97), and 85% (95% CI 76-91), respectively. CONCLUSIONS Prone acquisition and CTAC images improve the ability to assess the inferior/inferolateral area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease.

BACKGROUND Myocardial perfusion SPECT (MPS) traditionally requires the patient to be in the supine position, but diaphragmatic attenuation of the inferior wall reduces test specificity. The aim of this study was to assess the feasibility of combined MPS in the supine and prone positions using a novel cadmium zinc telluride (CZT) camera. METHODS AND RESULTS A total of 276 consecutive patients ...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Clinical Performance of the Discovery NM530c in Japanese Patients

The Discovery NM530 is a new generation of SPECT cameras equipped with semiconductor cadmium-zinctelluride (CZT) detector technology. It provides a shorter scan time and reduces the patient’s radiation exposure wthout loss of image quality compared with the conventional Anger camera. Combined supine and prone imaging with the Discovery NM530c is useful for reducing the false-positive rate in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2017