Chemiluminescent measurements of nitric oxide pulmonary diffusing capacity and alveolar production in humans.

نویسندگان

  • I B Perillo
  • R W Hyde
  • A J Olszowka
  • A P Pietropaoli
  • L M Frasier
  • A Torres
  • P T Perkins
  • R E Forster
  • M J Utell
  • M W Frampton
چکیده

Measurements of nitric oxide (NO) pulmonary diffusing capacity (DL(NO)) multiplied by alveolar NO partial pressure (PA(NO)) provide values for alveolar NO production (VA(NO)). We evaluated applying a rapidly responding chemiluminescent NO analyzer to measure DL(NO) during a single, constant exhalation (Dex(NO)) or by rebreathing (Drb(NO)). With the use of an initial inspiration of 5-10 parts/million of NO with a correction for the measured NO back pressure, Dex(NO) in nine healthy subjects equaled 125 +/- 29 (SD) ml x min(-1) x mmHg(-1) and Drb(NO) equaled 122 +/- 26 ml x min(-1) x mmHg(-1). These values were 4.7 +/- 0.6 and 4.6 +/- 0.6 times greater, respectively, than the subject's single-breath carbon monoxide diffusing capacity (Dsb(CO)). Coefficients of variation were similar to previously reported breath-holding, single-breath measurements of Dsb(CO). PA(NO) measured in seven of the subjects equaled 1.8 +/- 0.7 mmHg x 10(-6) and resulted in VA(NO) of 0.21 +/- 0.06 microl/min using Dex(NO) and 0.20 +/- 0.6 microl/min with Drb(NO). Dex(NO) remained constant at end-expiratory oxygen tensions varied from 42 to 682 Torr. Decreases in lung volume resulted in falls of Dex(NO) and Drb(NO) similar to the reported effect of volume changes on Dsb(CO). These data show that rapidly responding chemiluminescent NO analyzers provide reproducible measurements of DL(NO) using single exhalations or rebreathing suitable for measuring VA(NO).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rate of nitric oxide production by lower alveolar airways of human lungs.

This report describes methods for measuring nitric oxide production by the lungs' lower alveolar airways (VNO), defined as those alveoli and bronchioles well perfused by the pulmonary circulation. Breath holding or vigorous rebreathing for 15-20 s minimizes removal of NO from the lower airways and results in a constant partial pressure of NO in the lower airways (PL). Then the amount of NO diff...

متن کامل

A simultaneous single breath measurement of pulmonary diffusing capacity with nitric oxide and carbon monoxide.

Pulmonary diffusing capacity (DL) for carbon monoxide (CO) and nitric oxide (NO) were simultaneously measured in man using the single breath method, by adding 4O ppm of NO to the inspired gas and analysing the expirate for NO by a chemiluminescent method. The mean ratio of DLNO to DLCO in thirteen subjects was 4.3 (SD 0.3), mean DLNO = 49 mmol.min-1.kPa-1 (SD 10) and mean DLCO = 11 mmol.min-1.k...

متن کامل

Pulmonary membrane diffusing capacity and capillary blood volume measured during exercise from nitric oxide uptake.

STUDY OBJECTIVES To validate lung diffusing capacity for nitric oxide (DLNO) as an index of conductance of the alveolar-capillary membrane during exercise, we compared DLNO to lung diffusing capacity for carbon monoxide (DLCO) and pulmonary membrane diffusing capacity for carbon monoxide (DMCO), and compared pulmonary capillary blood volume (Vc) calculated by two methods. SETTING AND PARTICIP...

متن کامل

Pulmonary nitric oxide uptake reflects the entire diffusive properties of the alveolar capillary membrane.

Borland, Colin, Bryan Mist, Mariella Zammit, and Alain Vuylsteke. Steady-state measurement of NO and CO lung diffusing capacity on moderate exercise in men. J Appl Physiol 90: 538–544, 2001.—Using a rapidly responding nitric oxide (NO) analyzer, we measured the steady-state NO diffusing capacity (DLNO) from end-tidal NO. The diffusing capacity of the alveolar capillary membrane and pulmonary ca...

متن کامل

The lung diffusing capacity for nitric oxide in rats is increased during endotoxemia.

Rats, when injected with endotoxin, begin to exhale nitric oxide (NO) within 1 h. This study measured the diffusing capacity for NO in the lungs of rats (DL(NO)) under both control and endotoxemic conditions, and it also estimated the rate at which endogenous NO (VP(NO)) enters the distal compartment of the lung, both in control rats and during endotoxemia. DL(NO) increased from 0.68 +/- 0.12 (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 91 5  شماره 

صفحات  -

تاریخ انتشار 2001