The use of Geant4 for simulations of a plastic β-detector and its application to efficiency calibration
نویسندگان
چکیده
Precise β-branching-ratio measurements are required in order to determine ft-values as part of our program to test the Electroweak Standard Model via unitarity of the Cabibbo-Kobayashi-Moskawa matrix. For the measurements to be useful in this test, their precision must be close to 0.1%. In a branching-ratio measurement, we position the radioactive sample between a thin plastic scintillator used to detect β-particles, and a HPGe detector for γ-rays. Both β singles and β-γ coincidences are recorded. Although the branching ratio depends most strongly on the HPGe detector efficiency, it has some sensitivity to the energy dependence of the β-detector efficiency. We report here on a study of our β-detector response function, which used Monte Carlo calculations performed by the Geant4 toolkit. Results of the simulations are compared to measured β-spectra from several standard β-sources.
منابع مشابه
Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملOptical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes
The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...
متن کاملCalibration curves for on-line leakage detection using radiotracer injection method
One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملPhoton Flux Monitor for a Mono-energetic Gamma Ray Source
A novel photon flux monitor has been designed and tested for use at the Duke University High Intensity Gamma Source, where the photon beam produced is essentially mono-energetic but it is not tagged. Direct counting of the number of photons using a high-efficiency detector is not possible because of the high photon fluxes expected. Therefore, a direct counting detector with a low, accurately kn...
متن کامل