Sulfhemoglobinemia presenting as pulse oximetry desaturation.

نویسندگان

  • N Aravindhan
  • D G Chisholm
چکیده

SULFHEMOGLOBIN is a rare cause of cyanosis that is usually drug induced. The effects of sulfhemoglobin on pulse oximetry have not been reported widely. We present the case of a 48-yr-old woman who was scheduled to undergo palliative surgery. Before anesthesia, she had an oxygen saturation, measured by pulse oximetry (SpO2), of 85%. This apparent desaturation subsequently was discovered to be the result of a blood sulfhemoglobin concentration of 28%. She had been prescribed metoclopramide daily for more than 1 yr. Long-term ingestion of metoclopramide is a cause of drug-induced sulfhemoglobinemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methemoglobinemia and Sulfhemoglobinemia in Two Pediatric Patients after Ingestion of Hydroxylamine Sulfate

This case report describes two pediatric cases of immediate oxygen desaturation from methemoglobinemia and sulfhemoglobinemia after one sip from a plastic water bottle containing hydroxylamine sulfate used by a relative to clean shoes. Supplemental oxygen and two separate doses of methylene blue given to one of the patients had no effect on clinical symptoms or pulse oximetry. The patients were...

متن کامل

A case of sulfhemoglobinemia in a child with chronic constipation

Sulfhemoglobinemia is a rare condition in which a sulfur atom oxidizes the heme moiety in hemoglobin, making the hemoglobin incapable of carrying oxygen and leading to hypoxia and cyanosis. This condition has been described in patients taking sulfur medications or who have cultured hydrogen sulfide producing intestinal bacteria such as Morganella morganii. This case describes a pediatric patien...

متن کامل

فاکتورهای پیش بینی کننده کاهش اشباع اکسیژن خون شریانی در طی آندوسکوپی فوقانی در بیماران بدون دریافت داروی آرامبخش

Introduction: Hypoxemia can occur during upper gastrointestinal endoscopy with or without pharmacological sedation. Pulse oximetry saturation (SpO2) levels were assessed in patients attending for routine unsedated diagnostic upper gastrointestinal endoscopy to identify factors associated with oxygen desaturation. Methods: A total of 300 patients who underwent upper gastrointestinal endoscopy w...

متن کامل

Nocturnal desaturation: predictors and the effect on sleep patterns in patients with chronic obstructive pulmonary disease and concomitant mild daytime hypoxemia.

OBJECTIVE To determine the nocturnal oximetry pattern in chronic obstructive pulmonary disease patients having no sleep apnea and presenting mild daytime hypoxemia, to identify probable daytime parameters capable of predicting nocturnal desaturation, and to evaluate the influence of nocturnal desaturation on the sleep pattern of these patients. METHODS Twenty-five patients were divided into t...

متن کامل

Can pulse oximetry or a bedside swallowing assessment be used to detect aspiration after stroke?

BACKGROUND AND PURPOSE Desaturation during swallowing may help to identify aspiration in stroke patients. This study investigated pulse oximetry, bedside swallowing assessment (BSA), and videofluoroscopy as tests for detecting aspiration after stroke. METHODS Swallowing was assessed in 189 stroke patients (mean+/-SD age, 70.9+/-12.3 years) within 5 days of symptom onset with a modified BSA (w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 2000