A quality-control system for the "activated clotting time" test.

نویسندگان

  • F A Sedor
  • E Mayo
  • K E Kirvan
چکیده

with the following parameter changes: Sample volume 40 pipetting 2.0 mL of FFP into the calcium-adulterated ACT 4; Diluent volume 14 L; Calculation mode 0. When tube, and treat it as if it were a patient’s sample. modified as above, results are reported in milligrams per The precision ofthe FFP and AP’N’ systems is tabulated liter and cover the range 1.7-54.5 mg ofalbunun per liter. below: We assessed the precision of this method by multiple analyses ofserum (n = 24), CSF (n = 25), and urine (n = 25) containing 43 g/L, 130 mg/L, and 7.8 mgIL, respectively. APTT

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Platelet Factor 3 Based-clotting Time Assay as a Quality Marker for Long-term Storage of Platelet Concentrates

Background: Platelets rapidly lose their qualities usually after 5 day of storage. Different standard methods have been recommended to check the quality of platelets during storage which some of them show better correlation with other quality markers during storage. The purpose of this study was to demonstrate if platelet factor 3 (PF3) assay could be an indicator of storage lesion and provide ...

متن کامل

بررسی خون سازگاری سطح اپی تلیال پرده آمنیون در مقایسه با رگ صناعی (پلی تترافلورواتیلن)

Background and purpose: Amniotic membrane (AM) is a proper candidate for vascular tissue engineering. The aim of this study was to evaluate the hemocompatibility of the epithelial surface of the AM. Materials and methods: In this study, we assessed the effects of the epithelial surface of the AM on blood coagulation system by measuring activated partial thromboplastin time (aPTT), prothromb...

متن کامل

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....

متن کامل

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....

متن کامل

Validation of a new whole blood coagulation monitoring system.

The Hemochron Response is a third generation point-of-care (POC) whole blood coagulation analyzer that retains the clinical utility of the Hemochron standard (801/8000) while providing a data management program that assists the POC coordinator with Quality Assurance (QA) compliance. Clinical and laboratory studies were performed to ensure consistency of the target anticoagulation times with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 7  شماره 

صفحات  -

تاریخ انتشار 1987