Measurement of Fission Neutron Spectrum and Multiplicity using a Gamma Tag Double Time-of-flight Setup

نویسندگان

  • E. Blain
  • A. Daskalakis
  • Y. Danon
چکیده

Recent efforts have been made to improve the prompt fission neutron spectrum and nu-bar measurements for Uranium and Plutonium isotopes particularly in the keV region. A system has been designed at Rensselaer Polytechnic Institute (RPI) utilizing an array of EJ-301 liquid scintillators as well as lithium glass and plastic scintillators to experimentally determine these values. An array of BaF2 detectors was recently obtained from Oak Ridge National Laboratory to be used in conjunction with the neutron detectors. The system uses a novel gamma tagging method for fission which can offer an improvement over conventional fission chambers due to increased sample mass. A coincidence requirement on the gamma detectors from prompt fission gammas is used as the fission tag for the system as opposed to fission fragments in a conventional fission chamber. The system utilizes pulse digitization using Acqiris 8 bit digitizer boards which allow for gamma/neutron pulse height discrimination on the liquid scintillators during post processing. Additionally, a Cf fission chamber was designed and constructed at RPI which allowed for optimization and testing of the system without the need for an external neutron source. The characteristics of the gamma tagging method such as false detection rate and detection efficiency were determined using this fission chamber and verified using MCNP Polimi modeling. Prompt fission neutron spectrum data has been taken using the fission chamber focusing on the minimum detectable neutron energy for each of the various detectors. Plastic scintillators were found to offer a significant improvement over traditional liquid scintillators allowing energy measurements down to 50 keV. Background was also characterized for all detectors and will be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Measurement of Fission Neutron Multiplicity and Spectrum Using a Gamma Tagging Method

Ac There is currently a need for highly accurate measurements of fission neutron multiplicity ( ̅) and spectrum for U particularly in the range of sub 1 MeV fission neutron energy. These measurements increase the accuracy of calculations used to model nuclear fission systems. Gamma tagging is a new method for accurately measuring these quantities. This method utilizes an array of gamma detectors...

متن کامل

A method to measure prompt fission neutron spectrum using gamma multiplicity tagging

In order to improve on current prompt fission neutron spectrum measurements, a gamma multiplicity tagging method was developed at the Rensselaer Polytechnic Institute Gearttner Linear Accelerator Center. This method involves using a coincidence requirement on an array of BaF2 gamma detectors to determine the timing of a fission event. This allows for much larger fission samples to be used due t...

متن کامل

Characterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron

Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...

متن کامل

Modeling the measurement of VVER-1000 reactor power by neutron and gamma radiation with MCNP code

The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron ...

متن کامل

Shielding studies on a total-body neutron activation facility

Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014