Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery.

نویسندگان

  • G Biancofiore
  • L A H Critchley
  • A Lee
  • L Bindi
  • M Bisà
  • M Esposito
  • L Meacci
  • R Mozzo
  • P DeSimone
  • L Urbani
  • F Filipponi
چکیده

BACKGROUND The pulmonary artery catheter is invasive and may cause serious complications. A safe method of cardiac output (CO) measurement is needed. We have assessed the accuracy and reliability of a recently marketed self-calibrating arterial pulse contour CO monitoring system (FloTrac/Vigileo) in end-stage liver failure patients undergoing liver transplant. The pattern of alterations known as cirrhotic cardiomyopathy, and the transplant procedure itself, provided an evaluation under varying clinical conditions. METHODS The cardiac index was measured simultaneously by thermodilution (CI(TD): mean of four readings) using a pulmonary artery catheter and pulse contour analysis (CI(V): mean value computed by the FloTrac/Vigileo over the same time period). Readings were made at 10 time-points during liver transplant surgery (T1-T5) and on the intensive care unit (T6-T10). CI(V) was computed using the latest Vigileo software version 01.10. RESULTS A total of 290 paired readings from 29 patients were collected. Mean (SD) CI(TD) was 5.2 (1.3) and CI(V) was 3.9 (0.9) litre min(-1) m(-2), with a corrected for repeated measures bias between readings of 1.3 (0.2) litre min(-1) m(-2) and 95% limits of agreement of -1.5 (0.2) to 4.1 (0.3) litre min(-1) m(-2). The percentage error (2SD(Bias)/meanCI(TD)) was 54%, which exceeded a 30% limit of acceptance. Low peripheral resistance and increasing bias were related (r=0.69; P<0.001). The Vigileo system failed to reliably trend CI data, with a concordance compared with thermodilution below an acceptable level (at best 68% of sequential readings). CONCLUSIONS In cirrhotic patients with hyperdynamic circulation, the Vigileo system showed a degree of error and unreliability higher than that considered acceptable for clinical purposes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery

INTRODUCTION Uncalibrated arterial pulse power analysis has been recently introduced for continuous monitoring of cardiac index (CI). The aim of the present study was to compare the accuracy of arterial pulse power analysis with intermittent transpulmonary thermodilution (TPTD) before and after cardiopulmonary bypass (CPB). METHODS Forty-two patients scheduled for elective coronary surgery we...

متن کامل

A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery

Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary b...

متن کامل

Lack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery

Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 p...

متن کامل

Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.

BACKGROUND Cardiac output monitoring, as a part of a goal-directed haemodynamic management, has been shown to improve perioperative outcome in high-risk patients undergoing major surgical interventions. However, thorough validation of cardiac output monitoring devices in different clinical conditions is warranted. The aim of our study was to compare the reliability of a novel system for cardiac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 2009