The Angular Diameter of λ Boötis

نویسندگان

  • David R. Ciardi
  • Gerard T. van Belle
  • Andrew F. Boden
چکیده

Using the CHARA Array and the Palomar Testbed Interferometer, the chemically peculiar star λ Boötis has been spatially resolved. We have measured the limb darkened angular diameter to be θLD = 0.533 ± 0.029 mas, corresponding to a linear radius of R⋆ = 1.70±0.10 R⊙. The measured angular diameter yields an effective temperature for λ Boo of Teff = 8887±242 K. Based upon literature

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE ANGULAR DIAMETER OF k BOÖTIS

Using the CHARA Array and the Palomar Testbed Interferometer, the chemically peculiar star k Boötis has been spatially resolved.We havemeasured the limb darkened angular diameter to be LD 1⁄4 0:533 0:029mas, corresponding to a linear radius of R? 1⁄4 1:70 0:10R . Themeasured angular diameter yields an effective temperature for kBoo of TeA 1⁄4 8887 242 K. Based on literature surface gravity esti...

متن کامل

Modeling the Infrared Bow Shock at Δ Velorum: Implications for Studies of Debris Disks and Λ Boötis Stars

We have discovered a bow shock shaped mid-infrared excess region in front of δ Velorum using 24 μm observations obtained with the Multiband Imaging Photometer for Spitzer (MIPS). The excess has been classified as a debris disk from previous infrared observations. Although the bow shock morphology was only detected in the 24 μm observations, its excess was also resolved at 70 μm. We show that th...

متن کامل

Minimal Angular Size of Distant Sources in Open , Λ CDM , and Scalar Field Cosmologies

We propose a simple method for determining the redshift z m at which the angular size of an extragalactic source with fixed proper diameter takes its minimal value. A closed analytical expression, which is quite convenient for numerical evaluation is derived. The method is exemplified with the following FRW type expanding universes: the open matter dominated models (Ω Λ = 0), a critical density...

متن کامل

Size effect in equal channel angular pressing (ECAP) process

The influence of the sample size (diameter while keeping the length constant) in equal channel angular pressing (ECAP) of pure aluminum is examined using finite element method (FEM) and experiment. Different sized aluminum rods were processed via ECAP and the effect of sample size on the strain homogeneity, process load, and the ratio of the friction to the total force were evaluated. The resul...

متن کامل

The Brown-Twiss Radio-Wave Interferometer

Young noted (p. 464 of [2], with a figure appearing before p. 777) that if light from a “point” source passes through two slits (A and B in the right figure above), then a series of bright and dark “fringes” can be observed on a distant screen (CDEF). The angular separation of the bright (or dark) fringes is λ/d, where λ is the wavelength of the light and d is the spacing between the slits. If ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006