Direct visualization of epicardial structures and ablation utilizing a visually guided laser balloon catheter: preliminary findings.

نویسندگان

  • E Kevin Heist
  • Conor Barrett
  • Francesco Perna
  • Stephan Danik
  • Jeremy N Ruskin
  • Moussa Mansour
چکیده

BACKGROUND Intrapericardial mapping and ablation can be utilized to target epicardial arrhythmic circuits. Current epicardial ablation strategies are associated with risk of damage to adjacent structures, including the coronary vasculature and phrenic nerves. OBJECTIVES The purpose of this study was to evaluate the feasibility of an investigational, visually guided laser balloon catheter for manipulation within the pericardial space, visualization of epicardial structures, and delivery of laser ablation lesions to the ventricular myocardium. METHODS Pericardial access was obtained in 4 anesthetized swine by subxyphoid puncture. The laser balloon catheter was introduced into the pericardial space via a deflectable sheath, and was manipulated to predefined regions in all animals. Visually guided laser ablation was performed on the ventricular myocardium, with post mortem examination of lesion size and depth. RESULTS The laser ablation catheter could be manipulated to all targeted regions in all animals. Associated structures, including epicardial coronary arteries and veins as well as an endocardial catheter in the left atrial appendage, were easily visualized. A total of 9 laser energy applications at varying power/time settings were performed. Ablation utilizing moderate (7-8.5 W) power produced relatively uniform lesions (diameter 5-12 mm, depth 6-9 mm), while high (14 W) power produced a visible "steam pop" with a large, hemorrhagic lesion (22 × 11 × 11 mm). CONCLUSIONS The investigational laser balloon catheter can be manipulated within the epicardial space, allowing for direct visualization of surrounding structures during ablation. Titration of laser power can be utilized to create moderate-sized ablation lesions while avoiding steam pops.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The first human experience of a contact force sensing catheter for epicardial ablation of ventricular tachycardia

Contact force (CF) is one of the major determinants for sufficient lesion formation. CF-guided procedures are associated with enhanced lesion formation and procedural success. We report our initial experience in epicardial ventricular tachycardia (VT) ablation with a force-sensing catheter using a new approach with an angioplasty balloon. Two patients with arrhythmogenic right ventricular cardi...

متن کامل

Pulmonary vein isolation using a visually guided laser balloon catheter: the first 200-patient multicenter clinical experience.

BACKGROUND Because of the technical difficulty with achieving pulmonary vein (PV) isolation in the treatment of patients with paroxysmal atrial fibrillation, novel catheter designs to facilitate the procedure are in development. A visually guided laser ablation (VGLA) catheter was designed to allow the operator to directly visualize target tissue for ablation and then deliver laser energy to pe...

متن کامل

Visually-guided balloon catheter ablation of atrial fibrillation: experimental feasibility and first-in-human multicenter clinical outcome.

BACKGROUND Electric isolation of the pulmonary veins (PVs) can successfully treat patients with paroxysmal atrial fibrillation. However, it remains technically challenging to identify the left atrial-PV junction and sequentially position the ablation catheter in a point-by-point contiguous fashion to isolate the PVs. In this study, a novel endoscopic ablation system was used to directly visuali...

متن کامل

Hysteroscopic Subendometrial Embryo Delivery (SEED), Mechanical Embryo Implantation

Background A major hurdle to improved in vitro fertilization (IVF) success rate is defective endometrial receptivity and implantation. Various techniques have been advocated to increase implantation while reducing side effects. Currently, embryo transfer (ET) is performed blindly without direct visualization. As such, we sought to develop a technique utilizing a flexible minihysteroscope with a...

متن کامل

Creating Transmural, Linear Epicardial Ablation Lesions via a Non-surgical, Percutaneous, Subxyphoid, Electrogram-guided Approach

Surgical arrhythmia ablation techniques can achieve epicardial transmural lesions but require a combination of surgical access and endoscopic approaches. We sought to adapt a surgical ablation catheter to a percutaneous subxyphoid approach. The EpiSense nContact (Epi) is a surgical ablation catheter that contains a 3-cm ablation coil, an open irrigation system, and a suction mechanism to mainta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 22 7  شماره 

صفحات  -

تاریخ انتشار 2011