Inclinometer Assembly Error Calibration and Horizontal Image Correction in Photoelectric Measurement Systems
نویسندگان
چکیده
Inclinometer assembly error is one of the key factors affecting the measurement accuracy of photoelectric measurement systems. In order to solve the problem of the lack of complete attitude information in the measurement system, this paper proposes a new inclinometer assembly error calibration and horizontal image correction method utilizing plumb lines in the scenario. Based on the principle that the plumb line in the scenario should be a vertical line on the image plane when the camera is placed horizontally in the photoelectric system, the direction cosine matrix between the geodetic coordinate system and the inclinometer coordinate system is calculated firstly by three-dimensional coordinate transformation. Then, the homography matrix required for horizontal image correction is obtained, along with the constraint equation satisfying the inclinometer-camera system requirements. Finally, the assembly error of the inclinometer is calibrated by the optimization function. Experimental results show that the inclinometer assembly error can be calibrated only by using the inclination angle information in conjunction with plumb lines in the scenario. Perturbation simulation and practical experiments using MATLAB indicate the feasibility of the proposed method. The inclined image can be horizontally corrected by the homography matrix obtained during the calculation of the inclinometer assembly error, as well.
منابع مشابه
Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملBiaxial Angle Sensor Calibration Method Based on Artificial Neural Network
With regard to the nonlinearity, installation errors and other uncertainties existing in biaxial inclination sensors of borehole inclinometer, this article contrastively applies traditional curve fitting method and artificial neural network theory in the error correction work of inclinometer. Besides, this article also establishes the coordinate transformation model and gives details about the ...
متن کاملOptimizing the accuracy of a helical diode array dosimeter: a comprehensive calibration methodology coupled with a novel virtual inclinometer.
PURPOSE The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comp...
متن کاملDevelopment and calibration of an accurate 6- degree-of-freedom measurement system with total station
To meet the demand of high-accuracy, long-range and portable use in large-scale metrology for pose measurement, this paper develops a 6-degree-of-freedom (6-DOF) measurement system based on total station by utilizing its advantages of long range and relative high accuracy. The cooperative target sensor, which is mainly composed of a pinhole prism, an industrial lens, a camera and a biaxial incl...
متن کاملIntegrated Laser Scanner and Intensity Image Calibration and Accuracy Assessment
Nowadays, the use of laser scanner devices as an active technique for acquiring 3D information is growing fast. The huge amount of object points produced with less effort than other 3D acquisition techniques is one of the reasons for interest. For accurate measurements a sophisticated sensor model and calibration procedure is an important prerequisite of such an efficient system. The calibratio...
متن کامل