Altered left atrial compliance after atrial appendectomy. Influence on left atrial and ventricular filling.
نویسندگان
چکیده
Previous studies have shown regional differences in atrial distensibility. We studied 12 open-chest dogs to test the hypothesis that left atrial compliance is decreased after removal of the left atrial appendage and to determine the effect of altered atrial compliance on atrial reservoir and conduit function. Sonomicrometer crystal pairs were used to measure the long- and short-axis diameters of the left atrium over a wide range of intracardiac pressures and volumes obtained by intravenous hetastarch infusion both before and after suture ligation of the left atrial appendage (appendectomy). Pulmonary venous flow was measured with an ultrasonic flowmeter, and transmitral flow velocities were measured with transesophageal Doppler echocardiography. After appendectomy, the diastolic pressure-volume relation was shifted upward and to the left in six of seven dogs. The mean dynamic stiffness constant of the left atrial diastolic pressure-volume relation was significantly greater after appendectomy than before (0.20 +/- 0.11 [mean +/- SD] versus 0.14 +/- 0.08 ml-1, p < 0.01); the mean y intercept was slightly, but significantly, less after appendectomy (0.6 +/- 0.3 versus 1.3 +/- 0.6 mm Hg, p < 0.05). The left atrial reservoir volume (maximum minus minimum left atrial volume) was significantly less after appendectomy at matched left atrial pressures. The systolic to diastolic flow integral ratio of pulmonary venous flow (JFTI/KFTI), an index of the relative reservoir to conduit functions of the left atrium, increased significantly with volume infusion only before appendectomy; at matched left atrial pressure, JFTI/KFTI was significantly less afterwards.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Incidence of Atrial Fibrillation after Coronary Artery Bypass Graft Surgery and Its Risk Factors in Shiraz, Iran during 2017-18
Background and Objectives: Atrial fibrillation is one of the most common disorientations after coronary artery bypass graft surgery and can affect the chance of survival in the first year after surgery. The present study aimed to determine the incidence of atrial fibrillation after coronary artery bypass graft surgery and its risk factors. Methods: This cross-sectional study was performed on...
متن کاملAssessing atrial mechanical remodeling and its consequences.
The principal function of the left atrium is to modulate left ventricular (LV) filling and cardiovascular performance through reservoir, conduit, and booster pump functions; the latter is often (mistakenly) regarded synonymously with atrial function, and in contrast to the reservoir and conduit phases, has been studied extensively. Typically, the importance of atrial contraction has been estima...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملChanges in Left Ventricular Filling in Patients with Persistent Atrial Fibrillation
BACKGROUND Former studies showed possible interrelationship between altered ventricular filling patterns and atrial fibrillation (AF). HYPOTHESIS Long term persistent AF has a negative impact on left ventricular filling in patients with preserved ejection fraction of left ventricle. METHODS Our study was designed as a prospective case control study. We included 40 patients with persistent A...
متن کاملClinical Significance of P Wave Dispersion in Prediction of Atrial Fibrillation in Patients with Acute Myocardial Infarction
Background: P wave dispersion (PWD) is defined as the difference between the maximum P wave duration (Pmax) and the minimum P wave duration (Pmin) in 12-leads of the surface electrocardiography. The aim of this study was to evaluate the values of PWD during atrial fibrillation (AF) after acute myocardial infarction (AMI). Methods: We prospectively evaluated atrial rhythms of 350 patients (251 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 72 1 شماره
صفحات -
تاریخ انتشار 1993