The effect of bonded resin surface area on the detachment force of lingual bonded fixed retainers: An in vitro study

نویسندگان

  • Il-Hong Lee
  • Jung-Hwan Lee
  • In-Young Park
  • Ji-Hyun Kim
  • Jang-Hoon Ahn
چکیده

OBJECTIVE The aims of this study were to evaluate the relationship between the detachment force and bonding resin surface are and to determine the resin bonding surface area that would provide adequate bonding strength with minimum resin volume. METHODS One hundred and sixty human premolars were randomly divided into 4 groups of 40 teeth each. The diameter of the resin surface area in each group was as follows: group 1, 1.5 mm; group 2, 2.5 mm; group 3, 3.5 mm; and group 4, 4.5 mm. Respond Dead Soft straight (length 0.0175 inch) was used to fabricate the retainers, and Transbond™ XT was used to fix the retainers to the tooth surfaces. A pair of teeth was embedded in acrylic blocks for each specimen. Thus, each group comprised 20 samples. Fixed retainers were bonded to the teeth, and vertical force was applied at the middle of wire. The force was measured using a universal testing machine. RESULTS The mean value of detachment force was the highest for group 4 (102.38 ± 2.92 N), followed by group 3 (63.54 ± 2.21 N), group 2 (51.95 ± 1.61 N), and group 1 (24.14 ± 1.38 N). CONCLUSIONS The detachment force of lingual fixed retainers was significantly affected as the area of the resin bonding surface increased. Considering the minimum bonding strength of brackets, a resin bonding surface area with a diameter of 3.5 mm would provide adequate bonding strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the effects of different groove length and thickness of the retainers on the retention of maxillary anterior base metal resin bonded retainers-an in vitro study

OBJECTIVES The resin-bonded fixed partial dentures have gained immense popularity in recent years as they are more conservative, esthetic, economic and easily fabricated. However debonding is considered the most common cause of failure of resin bonded prosthesis. The objective of the study were to compare the effects of different groove lengths and thickness of retainers on retention of maxilla...

متن کامل

مقایسه استحکام باند برشی سه نوع سیستم رزینی جهت باند آلیاژ بیس متال به مینای دندان در In vitro

Resin-bonded fixed partial dentures (F.P.D) can be used for conservative treatment of partially edentulous patients. There are numerous studies regarding the strength of resin composite bond to base meta! alloys. Shear bond strength of three resin systems were invistigated. In this study these systems consisted of: Panavia Ex, Mirage FLC and Marathon V. Thirty base metal specimens were prepared...

متن کامل

Rebond strength of bonded lingual wire retainers.

There is no consensus in the literature concerning the rebonding procedure for orthodontic retainers. The aim of this in vitro study was to evaluate the bond and rebond strength of retainers bonded to enamel surfaces with and without composite remnants. The retainers were bonded with Excite and Tetric Flow on three different surfaces: clean enamel, enamel where the composite had been removed by...

متن کامل

An Overview of Fixed and Removable Orthodontic Retainers

 Background and purpose: One of the main challenges in orthodontic treatment is relapse after treatment and return of the teeth to its original position. Therefore, retainers are an essential part of orthodontic treatment. Fixed and removable retainers are commonly used in orthodontic retention. They prevent relapse and require patientchr('39')s cooperation in using them. This review study aime...

متن کامل

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

OBJECTIVE We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. METHODS We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2014