A misplaced and entrapped pulmonary artery catheter

نویسندگان

  • Soo-Kyung Park
  • Nam-Su Gil
  • Anna Kim
  • Ho-Geol Ryu
چکیده

Corresponding author: Ho-Geol Ryu, M.D., Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, 101, Daehag-ro, Jongro-gu, Seoul 110-744, Korea. Tel: 82-2-2072-2065, Fax: 82-2-747-5639, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. CC In 1970, Swan et al. [1] reported that a pulmonary capillary wedge pressure could be obtained by cardiac catheterization without the aid of fluoroscopy. Since then, the Swan-Ganz pulmonary artery catheter has been widely used to monitor hemodynamic changes and cardiac output in critically ill patients. A pulmonary artery catheter is placed through a large-bore introducer sheath and the right internal vein is preferred because of its straight course to the right atrium and right ventricle. Recently, we encountered a patient, in whom entrapment of the pulmonary artery catheter occurred as it entered the right ventricle, leading to catheter function failure. The patient required surgical removal of the catheter. A 66-year-old male was admitted for a transient ischemic attack. The patient had a history of hypertension and type II diabetes mellitus. The brain MRI/MRA revealed a total occlusion of the right proximal internal carotid artery, severe stenosis in the right proximal external carotid artery, and an atheromatous plaque with moderate narrowing of the left proximal internal carotid artery. To evaluate the cerebral vessels, a transfemoral cerebral angiography (TFCA) was performed. The patient had a mild stenotic artery with an ulcer in the left internal carotid artery. He was scheduled for a left carotid endarterectomy. To evaluate his heart function before surgery, a myocardial single-photon emission computed tomography was performed. A perfusion decrease in the basal anterior wall was found. A coronary angiography confirmed diffuse three vessel disease. After consultation between neurosurgery and cardiothoracic surgery, the patient was scheduled to undergo a simultaneous carotid endarterectomy and coronary artery bypass graft surgery. Before the induction of general anesthesia, the continuous arterial pressure was monitored by placing a 20-guaged catheter in the right radial artery. An induction was done using 5 mg of midazolam, 6 mg of etomidate, and 10 mg of vecuronium. After endotracheal intubation, an advanced venous access (AVA) catheter was placed in the right internal jugular vein under ultrasound guidance. Afterwards, the Swan-Ganz catheter (SGC) was inserted with the catheter tip facing the 9 o’clock direction. The catheter advanced smoothly up to 70 cm, but failed to reach the pulmonary artery and could not be advanced further. In the subsequent attempt, the catheter was inserted to 70 cm, but it was also unsuccessful. Resistance was felt when trying to withdraw the catheter for a third insertion attempt. The catheter withdrawal was immediately stopped, and a chest radiograph was performed and checked in the operating room. The chest radiograph showed an acute angulation of the SGC at the tip of the AVA catheter. Radiology consultation confirmed that the tip of the SGC was in the left azygous vein. There was no arrhythmia and the arterial pressure was stable throughout the insertionwithdrawal-reinsertion procedure. Following a successful carotid endarterectomy, the cardiac surgeon began coronary artery bypass graft surgery. After initiating a cardiopulmonary bypass, the SGC was retrieved. There was a small notch at the 40 cm mark of the catheter, but no evidence of knotting (Fig. 1). Several complications are associated with the insertion and presence of a SGC. A previous report showed that among 230 SGCs inserted, 9 (3.9%) were associated with major complications including a knotted catheter that had to be surgically removed [2]. Other reported complications include severe dysrhythmias (ventricular tachycardia or fibrillation)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inadvertent fracture during the attempted removal of entrapped Swan-Ganz catheter.

Dear Editor, Pulmonary artery catheter is widely used in cardiovascular surgical practice. Various complications of the Swan-Ganz catheter during insertion, its long-term placement, or removal are well known since its introduction.1-5 Herein, we report a case of the inadvertent fracture of an entrapped Swan-Ganz catheter during its attempted removal with moderate external traction. A 36-year-ol...

متن کامل

Successful retrieval of a knotted Swan-Ganz catheter using interventional approach in an adult: a case report.

Sir, Swan-Ganz catheterization, also known as the balloon tipped pulmonary artery catheterization, is widely used as a diagnostic and hemodynamic tool to monitor patients in the intensive care unit [1]. Knot formation is one of the rare complications with the incidence of 0.2−2.5%, which in general resulting in entrapping the catheter in the superior vena cava [2]. Surgical intervention is nece...

متن کامل

Surgical removal of entrapped and broken percutaneous transluminal coronary angioplasty balloon catheter.

OBJECTIVES The percutaneous coronary artery angioplasty is routinely being used worldwide for the management of short and discrete coronary artery stenosis. The purpose of this report is to address the potentially lethal complication among the variety of surgical problems in conjunction with this procedure. The case also illustrates the potential pitfalls in the management of CAD. METHODS A 6...

متن کامل

Intimal sarcoma of the pulmonary artery: diagnostic value of different imaging techniques.

1. Sharma SK, Bagga RS, Kini AS. Debulking approaches prior to stenting in interventional cardiology. In: Ellis SG, Holmes DR, editors. Strategic approaches in coronary intervention. 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2006. p. 116-24. 2. Alexiou K, Kappert U, Knaut M, Matschke K, Tugtekin SM. Entrapped coronary catheter remnants and stents: must they be surgically removed? Tex...

متن کامل

Entrapped Catheter across the Fossa Ovalis in an Adult with Pulmonary Stenosis - A Case Report of Surgical Relief

Percutaneous pulmonary balloon valvuloplasty as a procedure of choice in adults has been established since the last three decades. Even though the complications are rare, they are scarcely reported in the literature. We report such a case in an adult female patient of severe pulmonary valular stenosis in whom, entrapped catheter across the fossa ovalis was noted in chest x-ray and echocardiogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 64  شماره 

صفحات  -

تاریخ انتشار 2013