Concentric needle single fiber electromyography: normative jitter values on voluntary activated Extensor Digitorum Communis.

نویسندگان

  • João Aris Kouyoumdjian
  • Erik V Stålberg
چکیده

Single fiber electromyography (SFEMG) is the most sensitive clinical neurophysiological test for neuromuscular junction disorders, particularly myasthenia gravis. Normal values for jitter obtained with SFEMG electrode have been published, but there are few publications for concentric needle electrode (CNE). The aim of this study was to discuss the possibilities to analyse the jitter in CNE recordings and to get normal values of jitter for voluntary activated Extensor Digitorum Communis using disposable CNE. Fifty normal subjects were studied, 16 male and 34 female with a mean age of 37.1+/-10.3 years (19-55). The jitter values of action potentials pairs of isolated muscular fibers were expressed as the mean consecutive difference (MCD) after 20 analysed potential pairs. The mean MCD (n=50) obtained was 24.2+/-2.8 micros (range of mean values in each subject was 18-31). Upper 95% confidence limit is 29.8 micros. The mean jitter of all potential pairs (n=1000) obtained was 24.07+/-7.30 micros (range 9-57). A practical upper limit for individual data is set to 46 micros. The mean interpotential interval (MIPI) was 779+/-177 micros (range of individual mean values was 530-1412); there were no potentials with impulse blocking. The present study confirms that CNE is suitable for jitter analysis although certain precautions must be mentioned. Our findings of jitter values with CNE were similar to some other few reports in literature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concentric needle single fiber electromyography: comparative jitter on voluntary-activated and stimulated Extensor Digitorum Communis.

OBJECTIVE To compare the jitter values in voluntarily activated (v-CNE) and stimulated (s-CNE) techniques for Extensor Digitorum Communis muscle using a disposable concentric needle electrode (CNE). Quantifying jitter using a CNE in conjunction with a stimulated technique has not been reported previously. METHODS Forty-one normal subjects were studied, 15 male and 26 female with a mean age of...

متن کامل

Single - fiber EMG in Meniere ' s Disease

Objective: To assess neuromuscular transmission (NMT) in patients with Meniere's disease (MD), in which the precise etiology is unknown and a channelopathy hypothesis has been proposed Methods: Single fiber electromyography (SFEMG) during voluntary contraction of the extansor digitorum communis muscle, nerve conduction studies of upper and lower extremities and concentric needle electromyograph...

متن کامل

2.5 Mune (motor Unit Number Estimate)

[1] Benatar M, Hammad M, Doss-Rinev H. Concentric-needle fiber electromyografy for the diagnosis of myasthenia gravis. Muscle Nerve 2006; 34: 163–168 [2] Bischoff C. Bedeutung der Einzelfaser-Elektromyografie für die Diagnostik neuromuskulärer Erkrankungen. Klin Neurophysiol 2000; 31: 136–143 [3] Bischoff C. Einzelfaser-EMG mit konzentrischen Nadelelektrode: eine Alternative in der Diagnositik ...

متن کامل

Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles.

The aim of this study was to estimate normal jitter in voluntarily activated extensor digitorum communis (EDC) and orbicularis oculi (OOc) muscles using a disposable concentric needle electrode (CNE). The EDC of 67 normal subjects (22 males and 45 females, mean age 35.5 +/- 10.2 years) and the OOc of 50 normal subjects (13 males and 37 females, mean age 37.9 +/- 9.6 years) were studied. Jitter ...

متن کامل

Quantitating Changes in Jitter and Spike Number Using Concentric Needle Electrodes in Amyotrophic Lateral Sclerosis Patients

BACKGROUND Single-fiber electromyography (SFEMG) has been suggested as a quantitative method for supporting chronic partial denervation in amyotrophic lateral sclerosis (ALS) by the revised EI Escorial criteria. Although concentric needle (CN) electrodes have been used to assess jitter in myasthenia gravis patients and healthy controls, there are few reports using CN electrodes to assess motor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos de neuro-psiquiatria

دوره 65 2B  شماره 

صفحات  -

تاریخ انتشار 2007