Hybrid capture-II and LCR-E7 PCR assays for HPV typing in cervical cytologic samples.

نویسندگان

  • H Yamazaki
  • T Sasagawa
  • W Basha
  • T Segawa
  • M Inoue
چکیده

As part of an ongoing cohort study in the Hokuriku region of Japan, cervical cell samples from histologically confirmed normal (n = 114) or abnormal (n = 286) women were examined for the presence of HPV DNA using a second-generation hybrid capture assay (HCA-II) and LCR-E7 PCR. HCA-II detected low-risk (HPV-6, -11, -42, 43 and -44) and high-risk (HPV-16, -18, -31, -33, -35, -39, -45, -51, -52, -56, -58, -59 and -68) HPV types, while LCR-E7 PCR detected an additional 7 HPV types and some uncharacterized types. In screening of high-grade squamous intraepithelial lesions (HSILs) and invasive cervical cancer, the sensitivities of HCA-II and LCR-E7 PCR testing the high-risk HPV types were 83% and 81%, respectively, while the specificity of both assays was 93%. The sensitivity of LCR-E7 PCR increased to 87%, which was significantly higher than that in HCA-II, when testing both high-risk and other HPV types. Sixty-eight inconsistent results (17% of total tested) from HCA-II and LCR-E7 PCR were due to (i) low copy number of HPV genome (false-negative for HCA-II, 5.3% and for LCR-E7 PCR, 1.3%), (ii) infection with HPV types undetectable by HCA-II (4.8%), (iii) multiple HPV infections (5%) or (iv) unknown reasons (0.8%). LCR-E7 PCR revealed that infections with HPV-16, -18, -31, -33, -35, -51, -52, -56, -58 or -67 was a high risk for cancer since these types predominated in HSIL and invasive cervical cancer. Samples showing high relative light units (>20) with a high-risk probe in HCA-II also gave positive results in LCR-E7 PCR and were generally associated with abnormal cervical lesions. Thus, we propose that both HCA-II and LCR-E7 PCR are valuable screening tests for premalignant and malignant cervical lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative analysis of three methods for HPV DNA detection in cervical samples.

High risk HPV infection is considered to play a central role in cervical carcinogenesis. HPV DNA testing has shown to be a very useful tool for screening and following cervical infections. The aim of this study was to compare three methods for HPV DNA detection, along with cytology and colposcopy analysis. Cervical samples were collected from 100 sexually active women in Mérida, western Venezue...

متن کامل

Comparison of human papillomavirus detection and typing by cycle sequencing, line blotting, and hybrid capture.

We compared the results of human papillomavirus (HPV) detection and typing from 781 cervical samples assayed by three methods: L1 consensus PCR followed by cycle sequencing, L1 consensus PCR with biotinylated primers followed by hybridization to a line blot, and Hybrid Capture assay. Both PCR assays used L1 consensus PCR with primers MY09 and MY11. We evaluated the amplification efficiencies of...

متن کامل

Prevalence and predictors of human papillomavirus infection in women in Ontario, Canada. Survey of HPV in Ontario Women (SHOW) Group.

BACKGROUND Human papillomavirus (HPV) is thought to be the primary cause of cervical intraepithelial neoplasia and cervical cancer. We determined the age-specific prevalence of HPV infection and its risk factors in Ontario women. METHODS We obtained 2 cervical specimens from randomly selected women (in 5-year age categories, from 15 to 49 years) who were being seen in 32 family practices for ...

متن کامل

Comparison of the Novel Human Papillomavirus 4 Auto-capillary Electrophoresis Test with the Hybrid Capture 2 Assay and with the PCR HPV Typing Set Test in the Detection of High-Risk HPV Including HPV 16 and 18 Genotypes in Cervical Specimens

The aim of this study was to compare the novel human papillomavirus (HPV) detection method, the HPV 4 Auto-capillary Electrophoresis (ACE) test with the hybrid capture (HC) 2 assay for the detection of high-risk HPVs. In addition, we compared the HPV 4 ACE test with the polymerase chain reaction HPV Typing Set test for the detection of HPV 16 and HPV 18 genotypes. One hundred ninety-nine cervic...

متن کامل

Detection of human papillomavirus in cervical cell specimens by hybrid capture and PCR with different primers.

The purpose of this study was to compare hybrid capture assay with PCRs using different primers for the L1, E6-E7 regions for the detection of human papillomavirus (HPV) genome. One hundred twenty-five cervical smears with normal (n=42) and abnormal (n=83) cytology were investigated. Those at high-risk for HPV were studied by hybridization antibody capture assay and PCR with the pU-1M/pU-2R pri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of cancer

دوره 94 2  شماره 

صفحات  -

تاریخ انتشار 2001