The variability of femoral rotational alignment in total knee arthroplasty.
نویسندگان
چکیده
BACKGROUND Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if navigation systems can improve the accuracy of femoral rotational alignment as compared with that achieved with more traditional techniques involving mechanical guides. The purposes of the present study were to characterize the variability associated with femoral rotational alignment techniques and to determine whether the use of a computer-assisted surgical navigation system reduced this variability. METHODS Eleven orthopaedic surgeons used five alignment techniques (including one computer-assisted technique and four traditional techniques) to establish femoral rotational alignment axes on ten cadaveric specimens, and the orientation of these axes was recorded with use of a navigation system. These derived axes were compared against a reference transepicondylar axis on each femur that was established after complete dissection of all soft tissues. RESULTS There was no difference between the mean errors of all five techniques (p > 0.11). Only 17% of the knees were rotated <5 degrees from the reference transepicondylar axis, with alignment errors ranging from 13 degrees of internal rotation to 16 degrees of external rotation. There were significant differences among the surgeons with regard to their ability to accurately establish femoral rotational alignment axes (p < 0.001). CONCLUSIONS All techniques resulted in highly variable rotational alignment, with no technique being superior. This variability was primarily due to the particular surgeon who was performing the alignment procedure. A navigation system that relies on directly digitizing the femoral epicondyles to establish an alignment axis did not provide a more reliable means of establishing femoral rotational alignment than traditional techniques did.
منابع مشابه
Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)
Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملA clinical study of the rotational alignment of the femoral component in total knee arthroplasty
We describe here various surgical options to obtain a correct rotational alignment of femoral component in total knee arthroplasty (TKA). The correct rotational alignment is the key point to obtain a rectangular balanced flexion gap as well to have a good patellar tracking. For that reason, rotation alignment largely affects postoperative kinematic results particularly during flexion.
متن کاملA simple method for accurate rotational positioning of the femoral component in total knee arthroplasty
Background and purpose - There are many techniques for placing the femoral component in correct rotational alignment in total knee arthroplasty (TKA), but only a few have been tested against the supposed gold standard, rotation determined by postoperative computed tomography (CT). We evaluated the accuracy and variability of a new method, the clinical rotational axis (CRA) method, and assessed ...
متن کاملEffects of Implant Alignment on Passive Knee Envelope
INTRODUCTION: A successful surgical outcome in total knee arthroplasty (TKA) depends on multiple factors, including proper rotational and translational alignment of the femoral and tibial components. Small variation in surgical alignment of an implant could potentially have a large impact on knee performance. Several authors have studied the effects of tibial and femoral component’s internal-ex...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 87 10 شماره
صفحات -
تاریخ انتشار 2005