Noise Texture Deviation: A Measure for Quantifying Artifacts in Computed Tomography Images With Iterative Reconstructions.

نویسندگان

  • Fabian Morsbach
  • Lotus Desbiolles
  • Rainer Raupach
  • Sebastian Leschka
  • Bernhard Schmidt
  • Hatem Alkadhi
چکیده

OBJECTIVES The aims of this study were to introduce the measure noise texture deviation as quantitative parameter for evaluating iterative reconstruction (IR)-specific artifacts in computed tomography (CT) images and to test whether IR-specific artifacts, quantified through this measure, are reduced in advanced modeled IR (ADMIRE) as compared with sinogram-affirmed IR (SAFIRE) images of the liver ex vivo and in patients with hypodense liver lesions. MATERIALS AND METHODS In the ex vivo study part, an abdominal phantom was used. In the institutional review board-approved in vivo study part, 40 consecutive patients (mean age, 63 years) with hypodense liver lesions undergoing abdominal CT in the portal-venous phase were included. Images were reconstructed with filtered back projection, with the second-generation IR algorithm SAFIRE and with the third-generation IR algorithm ADMIRE. Noise power spectra and noise texture deviation were calculated in the phantom; image noise was measured in the phantom and in patients. Two blinded readers evaluated all image data regarding IR-specific artifacts (plastic-like, blotchy appearance); patient data were evaluated regarding conspicuity and confidence for detecting hypodense liver lesions. RESULTS Image noise was significantly reduced at increasing IR levels (P < 0.001) with both algorithms, with no significant differences between corresponding strength levels of SAFIRE and ADMIRE (all, P > 0.05). Noise power spectra were similar at corresponding strength levels of SAFIRE and ADMIRE (all, P > 0.05). Noise texture deviation in ADMIRE was reduced compared with corresponding strength levels of SAFIRE (all, P < 0.001) and strongly correlated with subjective IR-specific artifacts (r = 0.88, P < 0.001). Iterative reconstruction-specific artifacts were significantly reduced in ADMIRE compared with that in SAFIRE images at strength levels 3 or greater, both ex vivo and in vivo (all, P < 0.001). There were no significant differences in the readers' ratings of lesion conspicuity and lesion confidence in detecting hypodense liver lesions between SAFIRE and ADMIRE (P > 0.05). Only lesion conspicuity was superior with SAFIRE and ADMIRE compared with filtered back projection (all, P < 0.001). CONCLUSIONS Noise texture deviation is a quantitative measure reflecting IR-specific artifacts and is reduced in CT images with ADMIRE compared with SAFIRE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Comparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques

Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2017