Effect of experimental glaucoma in primates on oscillatory potentials of the slow-sequence mfERG.
نویسندگان
چکیده
PURPOSE To determine the effect of experimental glaucoma in macaque monkeys on oscillatory potentials (OPs) in the slow-sequence multifocal electroretinogram (mfERG). METHODS Photopic slow-sequence mfERGs were recorded from anesthetized adult macaque monkeys and normal human subjects. The stimulus consisted of 103 equal-sized hexagons within 17 degrees of the fovea. The m-sequence was slowed, with 14 blank frames, approximately 200 ms, interleaved between flashes for monkeys and 7 blank frames, approximately 100 ms, for humans, to produce waveforms similar to the photopic full-field flash ERG. Recordings were made under control conditions (24 monkey eyes, 7 human) and after laser-induced experimental glaucoma in monkeys (n = 8). A Fourier fast transform [FFT] was used to determine the frequency ranges of the major OPs. OP amplitudes were quantified by using root mean square (RMS) for two-frequency bands in five horizontal and four vertical locations. Visual field defects were assessed using behavioral static perimetry. Full-field photopic flash ERGs also were recorded. RESULTS OPs in two distinct frequency bands were discriminated in the monkey mfERG: fast OPs, with a peak frequency of 143 +/- 20 Hz, and slow OPs, with a peak at 77 +/- 8 Hz. There were similar findings in humans and with the flash ERG in monkeys. The fast OP RMS in monkey control eyes was significantly larger in temporal than nasal retina (P < 0.01) and in superior versus inferior retina (P < 0.05) as reported previously. The slow OP RMS was largest in the foveal region. Experimental glaucoma reduced fast OP RMS in all locations studied, even when visual field defects were moderate (MD = -5 to -10 dB; P < 0.05), whereas the slow OP RMS was reduced significantly primarily in the foveal region when field defects were severe (MD < -10 dB; P < 0.05). The fast OP RMS showed a moderate correlation with local visual field sensitivity and with local ganglion cell density (calculated from visual field sensitivity). For the slow OPs the correlation was much poorer. Consistent with previous studies, the photopic negative response (PhNR) amplitude was significantly reduced when the visual sensitivity was minimally affected. CONCLUSIONS OPs in the ERG of primates fall in two frequency bands: fast OPs with a peak frequency around 143 Hz and slow OPs, with a peak frequency around 77 Hz. The fast OPs, which rely more on the integrity of retinal ganglion cells and their axons than do the slow OPs, have potential utility for monitoring the progression of glaucoma and the effects of treatment.
منابع مشابه
Oscillatory potentials of the slow-sequence multifocal ERG in primates extracted using the Matching Pursuit method
This study used the Matching Pursuit (MP) method, a time-frequency analysis, to identify and characterize oscillatory potentials (OPs) in the primate electroretinogram (ERG). When the slow-sequence mfERG from the macular region of the retina was matched with Gabor functions, OPs were identified in two distinct bands: a high-frequency band peaking around 150 Hz that contributes to early OPs, and...
متن کاملEvaluation of inner retinal function in myopia using oscillatory potentials of the multifocal electroretinogram
PURPOSE Oscillatory potentials have been suggested to arise from the inner retina at the level of amacrine cells and inner plexiform layer and they are thought to provide a non-invasive assessment of inner retinal function. We sought to investigate the response dynamics of the inner retina of adult emmetropes and myopes by analysing the oscillatory potentials of the multifocal electroretinogram...
متن کاملMultifocal ERG wavelet packet decomposition applied to glaucoma diagnosis
BACKGROUND Glaucoma is the second-leading cause of blindness worldwide and early diagnosis is essential to its treatment. Current clinical methods based on multifocal electroretinography (mfERG) essentially involve measurement of amplitudes and latencies and assume standard signal morphology. This paper presents a new method based on wavelet packet analysis of global-flash multifocal electroret...
متن کاملLocal neuroretinal function during acute hypoxia in healthy older people.
PURPOSE To measure the effect of acute, mild, systemic hypoxia on neuroretinal function in two different age groups. METHODS The slow-flash paradigm of the multifocal electroretinogram (mfERG) was measured in two different oxygenation levels. Twelve participants of two age groups (28 +/- 4 and 55 +/- 5 years) breathed room air (normoxia) or 12% oxygen (hypoxia). RESULTS During normoxia (SaO...
متن کاملMacular Structure and Function in Nonhuman Primate Experimental Glaucoma
PURPOSE To evaluate structure and function of macular retinal layers in nonhuman primate (NHP) experimental glaucoma (EG). METHODS Twenty-one NHP had longitudinal imaging of macular structure by SDOCT, 16 also had recordings of function by multifocal ERG. The average thickness over 15° was derived for seven individual SDOCT layers: macular nerve fiber layer (m-NFL), retinal ganglion cell laye...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2006