Resolution in Electron Microscope Radioautography

نویسندگان

  • M. M. Salpeter
  • L. Bachmann
  • E. E. Salpeter
چکیده

Experimental resolution values, half distances (HD), were determined for electron microscope radioautography with (14)C as the source of radioactivity. These were about a factor of 1.5-2 times higher than for tritium. Grain distributions normalized in units of HD were found to fit the "universal" curves previously obtained for tritium.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electron Microscopic Radioautography of Thin Sections: the Golgi Zone as a Site of Protein Concentration in Pancreatic Acinar Cells

Electron microscopic radioautographs of guinea pig pancreatic exocrine cells were obtained by covering thin sections ( approximately 600 A) of OsO(4)-fixed, methacrylate-embedded tissue with thin layers of Ilford K-5 nuclear research emulsion. After an exposure of 13 days at 4 degrees C., the preparations were photographically processed, stained with uranyl acetate, and examined in an electron ...

متن کامل

A QUANTITATIVE TOOL IN ENZYME CYTOCHEMISTRY I. The Distribution of Acetylcholinesterase at Motor End Plates of a Vertebrate Twitch Muscle

Tritiated diisopropylfluorophosphate (DFP) was used to phosphorylate acetylcholinesterase (AChase) in the motor end plate of mouse sternomastoid muscle, and its distribution within the end plate was evaluated quantitatively by electron microscope radioautography. With the use of emulsion layers whose sensitivity to tritium had been calibrated, the density of AChase in different components of th...

متن کامل

Electron Microscope Radioautography as a Quantitative Tool in Enzyme Cytochemistry

Tritiated diisopropylfluorophosphate (DFP) was used to phosphorylate acetylcholinesterase (AChase) in the motor end plate of mouse sternomastoid muscle, and its distribution within the end plate was evaluated quantitatively by electron microscope radioautography. With the use of emulsion layers whose sensitivity to tritium had been calibrated, the density of AChase in different components of th...

متن کامل

Protein Synthesis in the Visual Cells of the Honeybee Drone as Studied with Electron Microscope Radioautography

Protein synthesis was studied in the visual cells of an insect (honeybee drone, Apis mellifera) by electron microscope radioautography. After a single injection of tritiated leucine, the radioactivity first appears in the cytoplasm of the visual cell which contains ribosomes. Later, part of this radioactivity migrates to the rhabdome, the visual cell region which is specialized in light absorpt...

متن کامل

DNA SYNTHESIS IN THE RAT ANTERIOR PITUITARY An Electron Microscope Radioautographic Study

The anterior pituitary gland has been classified by Leblond and Walker (1) as an organ of low mitosis and no cell renewal . Although mi oses in the gland are rarely seen (2-4), recent radioautographic studies have shown that thymidine3H is incorporated into rat anterior pituitary nuclei in vivo (5, 6) . We have shown by light microscope radioautography that thymidine-3H is also incorporated int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of Cell Biology

دوره 50  شماره 

صفحات  -

تاریخ انتشار 1969