Outcome measure for the treatment of cone photoreceptor diseases: orientation to a scene with cone-only contrast

نویسندگان

  • Alejandro J. Roman
  • Artur V. Cideciyan
  • Rodrigo Matsui
  • Rebecca Sheplock
  • Sharon B. Schwartz
  • Samuel G. Jacobson
چکیده

BACKGROUND Inherited retinal degenerations (IRDs) preferentially affecting cone photoreceptor function are being considered for treatment trials aiming to improve day vision. The purpose of the current work was to develop cone-specific visual orientation outcomes that can differentiate day vision improvement in the presence of retained night vision. METHODS A lighted wall (1.4 m wide, 2 m high) resembling a beaded curtain was formed with 900 individually addressable red, blue and green LED triplets placed in 15 vertical strips hanging 0.1 m apart. Under computer control, different combination of colors and intensities were used to produce the appearance of a door on the wall. Scotopically-matched trials were designed to be perceptible to the cone-, but not rod-, photoreceptor based visual systems. Unmatched control trials were interleaved at each luminance level to determine the existence of any vision available for orientation. Testing started with dark-adapted eyes and a scene luminance attenuated 8 log units from the maximum attainable, and continued with progressively increasing levels of luminance. Testing was performed with a three-alternative forced choice method in healthy subjects and patients with Leber congenital amaurosis (LCA) caused by mutations in GUCY2D, the gene that encodes retinal guanylate cyclase-1. RESULTS Normal subjects could perform the orientation task using cone vision at 5 log attenuation and brighter luminance levels. Most GUCY2D-LCA patients failed to perform the orientation task with scotopically-matched test trials at any luminance level even though they were able to perform correctly with unmatched control trials. These results were consistent with a lack of cone system vision and use of the rod system under ambient conditions normally associated with cone system activity. Two GUCY2D-LCA patients demonstrated remnant cone vision but at a luminance level 2 log brighter than normal. CONCLUSIONS The newly developed device can probe the existence or emergence of cone-based vision in patients for an orientation task involving the identification of a door on the wall under free-viewing conditions. This key advance represents progress toward developing an appropriate outcome measure for a clinical trial to treat currently incurable eye diseases severely affecting cone vision despite retained rod vision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new algorithm for optimum open pit design: Floating cone method III

Ultimate limits of an open pit, which define its size and shape at the end of the mine’s life, is the pit with the highest profit value. A number of algorithms such as floating or moving cone method, floating cone method II and the corrected forms of this method, the Korobov algorithm and the corrected form of this method, dynamic programming and the Lerchs and Grossmann algorithm based on grap...

متن کامل

Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications

Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...

متن کامل

Mega Voltage Cone Beam Computed Tomography (MV- CBCT) using a Standard Medical Linear Accelerator and EPID: A feasibility study.

Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...

متن کامل

Evaluation of Anatomical Variations of Paranasal Sinuses in Cone-beam Computed Tomography (CBCT) of Patients with Chronic Rhinosinusitis in Comparing with Normal Individuals

Introdouction: An exact knowledge of the anatomical variations of the paranasal sinuses (PNS) is critical for surgeons performing endoscopic sinus surgery and for radiologists involved in making preoperative evaluations. An important aspect is the determination of correlation between the anatomical variations of PNS and the presence of chronic rhinosinusitis (CR). Cone-beam computed tomograph...

متن کامل

Retinal morphology and retinomotor response in Caspian kutum (Rutilus frisii subsp. kutum)

In this study, the morphology and organization of the retina of Caspian kutum and fish response to ambient light as retinomotor reaction was investigated. The Rutilus frisii subsp. kutum is an anadromous fish and important native fish specimen of Caspian Sea. The specimens were obtained from Shahid Ansari Teleost Reproduction and Culture center (Guilan province, Iran). For light and dark adapta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015