Soft X-ray emissions of Si IX in Procyon
نویسندگان
چکیده
An analysis of n = 3 → 2 transition lines of carbon-like silicon reveals that some ratios of line intensities are sensitive to the electron density. The ratio between two group of 3d → 2p transition lines at 55.246 Å and 55.346 Å is a good ne-diagnostic technique, due to its insensitivity to the electron temperature. Using this property, a lower limit of the density of 0.6×10cm is derived for Procyon, which is consistent with that constrained by C V and Si X emissions. Significant discrepancies in ratios of 3s → 2p lines to 3d → 2p lines between theoretical predictions and observed values, are found, by the spectral analysis of Procyon observed with the Chandra High Resolution Transmission Grating spectra. The difference exceeding a factor of 3, cannot be explained by the uncertainty of atomic data. The opacity effect is also not a choice as reported by Ness and co-workers. For the 3s → 2p line at 61.611 Å , present work indicates that the large discrepancy may be due to the contamination from a S VIII line at 61.645 Å . For the lines at 61.702 and 61.846 Å , we suggest that the discrepancies may be attributed to contaminations of unknown lines. PACS: 95.20.Jg; 97.10.Ex; 95.85.Nv
منابع مشابه
Soft X - ray emissions of highly charged Si VII – Si XII in cool star – Procyon
Different observation data for cool star—Procyon (Obs IDs of 63, 1461 and 1224) available from Chandra Data Public Archive were co-added and analyzed. Emissivities of emission lines of highly charged silicon ions (Si VII–Si XII) were calculated over temperatures by adopting the published data of Liang et al. (2007, Atom. Data and Nucl. Data Tables, 93, 375). Using the emission measure derived b...
متن کاملCoronal density diagnostics with Si X : CHANDRA / LETGS observations of Procyon , α Cen A & B , Capella and ǫ Eri
Received ; accepted – 2 – ABSTRACT Electron density diagnostics based on a line intensity ratio of Si X are applied to the X-ray spectra of Procyon, α Cen A&B, Capella and ǫ Eri measured with the Low Energy Transmission Grating Spectrometer (LETGS) combined with High-resolution Camera (HRC) on board the Chandra X-ray Observatory. The ratio R 1 of the intensities of the Si X lines at 50.524Å and...
متن کاملبررسی فازی ترکیبات Mo + 2(1 - x) Si + 2xAl
X-ray powder diffraction data for Mo2.85Al1.91Si4.81 are presented here. The new Mo2.85Al1.91Si4.81 compound was successfully prepared, using the self-propagating high-temperature synthesis (SHS) technique. The starting atomic mixture of reactant powders was Mo + 2(1 - x)Si + 2xAl with 0.2 ≤ x ≤ 0.5. The final powder compound obtained by the SHS technique was determined to be in x = 0.2; Mo(Si,...
متن کاملLateral Soft Tissue X-ray for Patients with Suspected Fishbone in Oropharynx, A thing in the past
Introduction: Fishbone is the most common foreign body found in the oropharynx. Conventionally patients with suspected fishbone in the throat would have mirror laryngoscopy followed by lateral soft tissue X-ray to look for the fishbone or observe impacts caused by the fishbone i.e. soft tissue swelling or air in upper esophagus. However, the most common site of fishbone impact is the suprahyoid...
متن کاملمکانیسم تولید و ویژگیهای تابش چرنکوف در ناحیه اشعه ایکس نرم
In this paper, the production mechanisms and the spectral-angular distribution of X-ray Cherenkov radiation (XCR) was investigated in detail and some unique properties of XCR and its applications were discussed. It is shown that, in the vicinity of the atomic absorption edges, the real and the imaginary parts of the refractive index are varied drastically and for some materials the refractive i...
متن کامل