Estimation of free thyroxin with a new thyroxin analog and a porous-glass solid phase.

نویسندگان

  • L R Witherspoon
  • S E Shuler
  • S S Gilbert
چکیده

We evaluated a new thyroxin analog-based assay for free thyroxin (FT4) (Corning Medical), finding it technically simple and precise (between-assay CVs of 3.3 and 4.2% for FT4 concentrations of 12 and 25 ng/L, respectively). We measured FT4 in a total of 325 serum samples from euthyroid patients; patients receiving replacement thyroxin; patients receiving estrogens or who were pregnant; hyperthyroid, hypothyroid, and non- thyroidally ill patients; and patients receiving salicylates, phenytoin, or heparin. This assay clearly identified hyper- and hypothyroid patients, and produced similar results in euthyroid patients with above-normal, normal, or low concentration of thyroxin-binding globulin. Results in some non-thyroid-illness patients and patients receiving salicylates or phenytoin were low compared with euthyroid patients receiving no medications, but the diagnostic accuracy of the Corning FT4 assay exceeded that of another analog-based assay (Amersham) in these particular groups. We believe the new Corning analog FT4 assay offers an attractive alternative to other commercial FT4 systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex Free T4).

Serum free thyroxin (FT4) in normal nonpregnant and pregnant subjects was measured by radioimmunoassay (RIA) with Amerlex FT4 RIA (Amersham International) and LiquiSol FT4 RIA (Damon Diagnostics) kits. Amerlex FT4 values in serum from pregnant women were lower than those in serum from nonpregnant women, but LiquiSol FT4 values were similar in serum from both groups. Amerlex FT4 values were dire...

متن کامل

Study of a mechanism responsible for anomalous results for free thyroxin by some analog assays for subjects with albumin deficiency.

I examined the effect of albumin deficiency, as might occur in pregnancy and nonthyroidal illness, on four analog-based assays for free thyroxin (Amersham's Amerlex, Diagnostic Products Corporation's Coat-A-Count "one-step," Clinical Assays' Gammacoat "one-step," and Corning's Immophase "single-step"). In subjects with albumin deficiency per se, Amerlex and Coat-A-Count results for free thyroxi...

متن کامل

An inherited albumin variant with enhanced affinity for the Amerlex thyroxin-analog.

We describe two siblings with artefactually increased results for free thyroxin in serum as measured with the Amerlex analog method, despite normal thyroxin transport. The cause of the artefact is identified as a variant albumin with enhanced affinity for the Amerlex thyroxin-analog.

متن کامل

Effect of detergent on triglyceride assay.

2. Meinhold H, Wenzel KW. Comparative methodological studies with six commercial FF4 kits. Nucl Compact 1985;16:317-20. 3. Ross HA. An indirect assay for serum free thyroxin (FF4) using monoclonal antibody coated tubes and radiolabeled thyroxin. Ibid., 1985;32:314-6. 4. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassays for free thyroxin measure the albuminbound hor...

متن کامل

A longitudinal study of thyroid function in pregnancy.

We undertook a prospective longitudinal study of thyroid function in 36 pregnant women. There were significant increases in thyroxin-binding globulin, thyrotropin, and triiodothyronine. Albumin, free thyroxin (measured by an analog and a nonanalog method), and the free thyroxin index were significantly decreased. Results for the free thyroxin methods were correlated with each other in each trim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 1984