Increased maximum gradient amplitude improves robustness of spin-echo cardiac diffusion-weighted MRI

نویسندگان

  • Eric Aliotta
  • Stanislas Rapacchi
  • Peng Hu
  • Daniel B Ennis
چکیده

Background Cardiac motion presents a major challenge in diffusion weighted MRI (DWI), often leading to large signal dropouts that necessitate repeated measurements (Pai, V.M., MRM 2011). While cardiac DWI is generally ECG gated to apply diffusion weighting during peak-systole or enddiastole, these intervals can be short and difficult to pinpoint, resulting in poor sequence reproducibility. Recent improvements in gradient hardware provide larger maximum gradients than current systems (Gmax=80mT/m), which can substantially reduce the temporal footprint of diffusion preparation and make cardiac DWI more robust to bulk motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution spin-echo Cardiac Diffusion-Weighted MRI with motion compensated Convex Optimized Diffusion Encoding (CODE)

Background Cardiac Diffusion Weighted MRI (cDWI) has the potential to characterize myocardial infarction (MI) without contrast. However, the clinical utility of cDWI has been limited by severe sensitivity to cardiac motion that manifests as signal dropouts which corrupt measures of myocardial diffusivity. This can be managed by carefully timing the diffusion encoding gradients (GDiff) to a quie...

متن کامل

A spin echo sequence with a single-sided bipolar diffusion gradient pulse to obtain snapshot diffusion weighted images in moving media.

In vivo MRI data can be corrupted by motion. Motion artifacts are particularly troublesome in Diffusion Weighted MRI (DWI), since the MR signal attenuation due to Brownian motion can be much less than the signal loss due to dephasing from other types of complex tissue motion, which can significantly degrade the estimation of self-diffusion coefficients, diffusion tensors, etc. This paper descri...

متن کامل

A Monte Carlo study of the effects of cell membrane permeability on DWI-MRI contrast with oscillating diffusion gradients

Introduction: Recent interest in the use of oscillating diffusion gradients in diffusion-weighted magnetic resonance imaging (DWI-MRI) stems from simulated and experimental results indicating that, for given gradient performance parameters (max. amplitude, slew rate), an oscillating gradient spin echo (OGSE) sequence is capable of sampling shorter diffusion times than conventional pulsed gradie...

متن کامل

Echo Planar Diffusion-weighted Mri of the Abdomen and Pelvis: Comparison of Free- Breathing Monopolar and Bipolar Spin-echo Sequences in Image Quality and Geometric Distortions

Introduction: Diffusion-weighted magnetic resonance imaging (DWI) exploits the random, thermally induced displacement of water molecules in biological tissue. Most DWI applications in the abdomen and pelvis employ single-shot spin-echo echo-planar imaging (ssEPI) due to its fast acquisition times and resultant robust performance against motion artifacts. Nevertheless EPI-based DWI suffers from ...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015