Bioimpedance spectroscopy tensor probe for anisotropic measurements

نویسندگان

  • H. Kwon
  • H. Wi
  • B. Karki
  • E. J. Lee
  • A. McEwan
  • E. J. Woo
  • B. Harrach
  • J. K. Seo
  • T. I. Oh
چکیده

The tetrapolar electrode configuration used in bioimpedance suffers from negative sensitivity and is confounded by anisotropic tissue such as blood vessels or muscle and nerve fibres. We propose a circular array of electrodes to focus current directly underneath the probe and provide anisotropy information. We show that an implementation using 16 miniature electrodes is able to outperform the tetrapolar method in sensitivity and impedance estimation. The proposed method can also recover anisotropic conductivity tensors from experiments for the first time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Full Determination of the Rotational Diffusion Tensor by Electron Paramagnetic Resonance at 250 GHzf

High-frequency (250 GHz) electron paramagnetic resonance (EPR) spectra in the limit of motional narrowing have been studied for a nitroxide spin probe diffusing in a low-viscosity isotropic solvent. The enhanced sensitivity of the 250-GHz spectrum to rotational modulation of the g tensor reveals new details of the microscopic motion of the spin probe. Specifically, it is shown how independent l...

متن کامل

Prediction of Instability in Planar Anisotropic Sheet Metal Forming Processes

In this paper instability of planar anisotropic sheet metal during a few forming processes is investigated for the first time. For this reason components of the constitutive tangent tensor for planar anisotropic sheets are developed. By using the above tensor location of necking is predicted. Direction of the shear band is also predicted using the acoustic tensor. A finite element program is pr...

متن کامل

Diffusion properties of NAA in human corpus callosum as studied with diffusion tensor spectroscopy.

In diffusion tensor imaging (DTI) the anisotropic movement of water is exploited to characterize microstructure. One confounding issue of DTI is the presence of intra- and extracellular components contributing to the measured diffusivity. This causes an ambiguity in determining the underlying cause of diffusion properties, particularly the fractional anisotropy (FA). In this study an intracellu...

متن کامل

An analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applications.

The increasing number of applications of electrical bioimpedance measurements in biomedical practice, together with continuous advances in textile technology, has encouraged several researchers to make the first attempts to develop portable, even wearable, electrical bioimpedance measurement systems. The main target of these systems is personal and home monitoring. Analog Devices has made avail...

متن کامل

Detection and Classification of Measurement Errors in Bioimpedance Spectroscopy

Bioimpedance spectroscopy (BIS) measurement errors may be caused by parasitic stray capacitance, impedance mismatch, cross-talking or their very likely combination. An accurate detection and identification is of extreme importance for further analysis because in some cases and for some applications, certain measurement artifacts can be corrected, minimized or even avoided. In this paper we pres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012