Clock compensation in a data/fax relay system
نویسنده
چکیده
In Data/Fax relay applications, one challenge is to overcome problems associated with having independent clocks in the system. Due to slight differences in the clock frequency of the relay system compared to the far modems (fax machines), the relay system is unable to transmit with the same rate that it receives data. Eventually, the system either starves for data or loses data due to under/over flow of its buffers. The clock difference problem in a Demod/Remod system and a method to compensate for it is addressed in this paper. The transmitter clock in each side of the relay system is tuned to match with the clock rate at the other side. This clock tuning is done via a closed loop feedback system. The bit error rate measurements show a significant improvement in the performance of the Demod/Remod system when the clock difference is compensated.
منابع مشابه
Inverter based distributed generator islanding detection method using U/O voltage relay
Islanded operation of distributed generators is a problem that can take place when they are connected to a distribution system. In this paper an islanding detection method is presented for inverter based distributed generation (DG) using under/over voltage relay. The method is an adaptive one and is based on the change of DG active power reference (Pref) in inverter control interface. The activ...
متن کاملLatency-Insensitive Design for SHIM
II. BACKGROUND AND RELATED WORK Latency-insensitive design. Latency-insensitive design is a design methodology for robust synchronous digital system against arbitrary wire delays [1], [3]. In this framework, a welldesigned synchronous component (called a pearl module) in a system is encapsulated by shell logic, which is a simple logic controlling the communication and activation of the componen...
متن کاملPower Quality Impacts of Series and Shunt Compensated Lines on Digital Protective Relays
The proliferation of compensators, due to their nonlinear characteristics raises concern over the distortion levels they cause in voltages and currents at the transmission level. In this paper, series compensation by Thyristor Controlled Series Capacitor (TCSC) and shunt compensation by STATCOM are investigated in terms of power quality and their effects on protective relays behavior. For each ...
متن کاملA Nonlinear Abr Flow Control with Feed-forward Compensation for Atm Networks
In this paper the problem of flow control in fast, connection oriented communication networks supporting traffic generated by multiple sources is considered. The network is modelled as a dynamic system with different delay times. A nonlinear strategy governing the behaviour of the sources is proposed. The strategy combines Smith principle and feed-forward compensation with the conventional rela...
متن کاملPerformance Study of Untrusted Relay Network Utilizing Cooperative Jammer
Abstract—In this paper, the problem of secure transmission in two-hop amplify-and-forward (AF) systems with an untrusted relay is investigated. To prevent the untrusted relay from intercepting the source message and to achieve positive secrecy rate, the destination-based cooperative jamming (DBCJ) technique is used. In this method the destination sends an intended jamming signal to the relay. T...
متن کامل