High-resolution continuous-flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

نویسندگان

  • B. D. Emanuelsson
  • W. T. Baisden
  • N. A. N. Bertler
  • E. D. Keller
چکیده

Here we present an experimental setup for water stable isotope (δO and δD) continuous-flow measurements and provide metrics defining the performance of the setup during a major ice core measurement campaign (Roosevelt Island Climate Evolution; RICE). We also use the metrics to compare alternate systems. Our setup is the first continuousflow laser spectroscopy system that is using off-axis integrated cavity output spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research, LGR) in combination with an evaporation unit to continuously analyze water samples from an ice core. A Water Vapor Isotope Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to (1) enable measurements on several water standards, (2) increase the temporal resolution by reducing the response time and (3) reduce the influence from memory effects. While this setup was designed for the continuous-flow analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The custom setups provide a shorter response time (∼ 54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (∼ 62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the custom setups have a reduced memory effect. Stability tests comparing the custom and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the custom 2013 setup the precision after integration times of 10 s is 0.060 and 0.070 ‰ for δO and δD, respectively. The corresponding σAllan values for the custom 2014 setup are 0.030, 0.060 and 0.043 ‰ for δO, δD and δO, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042 ‰ after 10 s for δO, δD and δO, respectively. Both the custom setups and WVISS setup are influenced by instrumental drift with δO being more drift sensitive than δD. The σAllan values for δ O are 0.30 and 0.18 ‰ for the custom 2013 and WVISS setup, respectively, after averaging times of 10 s (2.78 h). Using response time tests and stability tests, we show that the custom setups are more responsive (shorter response time), whereas the University of Copenhagen (UC) setup is more stable. More broadly, comparisons of different setups address the challenge of integrating vaporizer/spectrometer isotope measurement systems into a CFA campaign with many other analytical instruments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High speed, high resolution, and continuous chemical analysis of ice cores using a melter and ion chromatography.

Measurement of trace chemical impurities in ice cores contributes to the reconstruction of records of the atmospheric environment and of the climate system. Ion chromatography (IC) is an effective analytical technique for ionic species in ice cores but has been used on discretely prepared ice samples, resulting in extensive and slow sample preparation and potential for contamination. A new tech...

متن کامل

Surface roughness over the northern half of the Greenland Ice Sheet from airborne laser altimetry

[1] Surface roughness, defined as the standard deviation of small-scale elevation fluctuations from the linear trend over 0.5 km, can be estimated from high-resolution airborne laser altimetry. Here we present results for the northern half of the Greenland Ice Sheet using laser data collected in May 1995. Roughness is smallest in the central region straddling the ice divide, increases in amplit...

متن کامل

Proxies and measurement techniques for mineral dust in Antarctic ice cores.

To improve quantitative interpretation of ice core aeolian dust records, a systematic methodological comparison was made. This involved methods for water-insoluble particle counting (Coulter counter and laser-sensing particle detector), soluble ion analysis (ion chromatography and continuous flow analysis), elemental analysis (inductively coupled plasma mass spectroscopy at pH 1 and after full ...

متن کامل

ELASTIC CONSTANTS OF ICE Ih, UP TO 2.8 KBAR, BY BRILLOUIN SPECTROSCOPY

The technique of high resolution Brillouin spectroscopy has been used to determine accurately the hydrostatic pressure dependence of the elastic constants of ice Ih in the full pressure range of phase stability 0 2.8 kbar. The percentage changes in the adiabatic elastic constants c,,, cI2. cI3, cS3, c,, and bulk modulus, over the pressure range, are 3.0, 7.2, 8.4, 2.8, -1.5 and 5.6 percent per ...

متن کامل

HIGH RESOLUTION LASER SPECTROSCOPY IN COLD SUPERSONIC MOLECULAR BEAMS COOLING, REDUCTION OF DOPPLER WIDTH AND APPLICATION

The cooling of molecules during the adiabatic expansion of supersonic seeded molecular beams is reviewed and illustrated by the example of NO -molecules. The reduction of the Doppler width by collimation of the beam and the cooling to low rotational temperatures brings a significant simplification of the complex NO -absorption spectrum and allows its assignment. The measured rotational tem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017