A model for studies of the deformable rib cage.

نویسندگان

  • R F Closkey
  • A B Schultz
  • C W Luchies
چکیده

An earlier model for the study of rib cage mechanics was modified so that rib deformity in scoliosis could be better represented. The rigid ribs of that model were replaced by five-segment deformable ribs. Literature data on cadaver rib mechanical behavior were used to assign stiffnesses to the new individual model ribs so that experimental and model rib deflections agreed. Shear and tension/compression stiffnesses had little effect on individual rib deformation, but bending stiffnesses had a major effect. Level-to-level differences in mechanical behavior could be explained almost exclusively by level to level differences in the rib shape. The model ribs were then assembled into a whole rib cage. Computer simulations of whole rib cage behaviors, both in vivo and in vitro, showed a reasonable agreement with the measured behaviors. The model was used to study rib cage mechanics in two scolioses, one with a 43 degrees and the other with a 70 degrees Cobb angle. Scoliotic rib cage deformities were quantified by parameters measuring the rib cage lateral offset, rib cage axial rotation, rib cage volume and rib distortion. Rib distortion was quantified both in best-fit and simulated computer tomography (CT) scan planes. Model rib distortion was much smaller in best-fit planes than in CT planes. The total rib cage volume changed little in the presence of the scolioses, but it became asymmetrically distributed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی

  Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...

متن کامل

The Effects of Rib Cage Compression before endotracheal suctioning

Abstract Introduction: Accumulation of secretions in airways is a serious complication in intubated and mechanically ventilated patients. Tracheal suctioning which is done with the aim of secretion removal can be used in conjunction with physiotherapy for effective airway clearance and improving gas exchange. Objective: The aim of study was to determine the effects of rib cage compression befor...

متن کامل

تاثیر فشردن قفسه‌ی سینه در زمان بازدم قبل از ساکشن داخل تراشه بر اکسیژناسیون خون شریانی بیماران تحت تهویه مکانیکی

Background and Objective: Hypoxia is a major problem in patients undergoing ventilation due to the high bronchioles secretion. This study aimed to determine the effect of expiratory rib-cage compression prior to endotracheal suctioning on arterial blood oxygenation (SpO2) in patients undergoing mechanical ventilation. Materials and Methods: This clinical trial with a crossover design included 5...

متن کامل

3D reconstruction of rib cage geometry from biplanar radiographs using a statistical parametric model approach

Rib cage 3D reconstruction is an important prerequisite for thoracic spine modelling, particularly for studies of the deformed thorax in adolescent idiopathic scoliosis. This study proposes a new method for rib cage 3D reconstruction from biplanar radiographs, using a statistical parametric model approach. Simplified parametric models were defined at the hierarchical levels of rib cage surface,...

متن کامل

Simulated Motion Artefact in Computed Tomography

We propose a simulation framework to simulate the computed tomography acquisition process. It includes five components: anatomic data, respiration modelling, automatic parametrisation, X-ray simulation, and tomography reconstruction. It is used to generate motion artefacts in reconstructed CT volumes. Our framework can be used to evaluate CT reconstruction algorithm with motion artefact correct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 1992