Development of miniature DC SQUID devices for the detection of single atomic spin-flips
نویسندگان
چکیده
We report progress toward a superconducting quantum interference device (SQUID)-based system capable of detecting a few atomic spin-flips. The scaling of the flux sensitivity with SQUID loop dimension of miniature niobium dc SQUID devices is examined and shown experimentally to vary as predicted. Our smallest device, with loop size 3 m 3 m, is capable of detecting 40 spins in a 1-Hz bandwidth. We address the task of depositing a sample, of nanoscale dimension, within the SQUID loop.
منابع مشابه
Detection of cryoglobulins in serum of Caspian miniature horse
Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was perform...
متن کاملترابرد الکتریکی وابسته به اسپین در ساختارهای نامتجانس Fe-MgO-Fe
In this paper, spin-dependent electrical transport properties are investigated in a single-crystal magnetic tunnel junction (MTJ) which consists of two ferromagnetic Fe electrodes separated by an MgO insulating barrier. These properties contain electric current, spin polarization and tunnel magnetoresistance (TMR). For this purpose, spin-dependent Hamiltonian is described for Δ1 and Δ5 bands in...
متن کاملABSTRACT Title of Dissertation: DESIGN OF A LARGE BANDWIDTH SCANNING SQUID MICROSCOPE USING A CRYOCOOLED HYSTERETIC DC SQUID
Title of Dissertation: DESIGN OF A LARGE BANDWIDTH SCANNING SQUID MICROSCOPE USING A CRYOCOOLED HYSTERETIC DC SQUID Soun Pil Kwon, Doctor of Philosophy, 2006 Dissertation directed by: Professor Frederick C. Wellstood Department of Physics I present the design and analysis of a large bandwidth scanning Superconducting Quantum Interference Device (SQUID) microscope. Currently available SQUID micr...
متن کاملInvestigation of Novel Transformerless Converters for DC Microgrid: Design and Analysis
This paper proposes two new soft-switching transformerless converters with high voltage conversion ratio. These proposed converters achieve soft-switching each with a single auxiliary resonant cell. The merit of these converters is reduced switching losses with lesser number of devices. The main switching devices are turned off with zero current switching (ZCS). Apart from the soft-switching fe...
متن کاملInteraction of atomic hydrogen with monometallic Au(100), Cu(100), Pt(100) surfaces and surface of bimetallic Au@Cu(100), Au@Pt(100) overlayer systems: The role of magnetism
The spin-polarized calculations in generalized gradient approximation density–functional theory (GGA–DFT) have been used to show how the existence of second metals can modify the atomic hydrogen adsorption on Au (100), Cu (100), and Pt (100) surfaces. The computed adsorption energies for the atomic hydrogen adsorbed at the surface coverage of 0.125 ML (monolayer) for the monometallic Au (100), ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Instrumentation and Measurement
دوره 50 شماره
صفحات -
تاریخ انتشار 2001