Initial operation of a pulse-burst laser system for high-repetition-rate Thomson scattering.

نویسندگان

  • W S Harris
  • D J Den Hartog
  • N C Hurst
چکیده

A pulse-burst laser has been installed for Thomson scattering measurements on the Madison Symmetric Torus reversed-field pinch. The laser design is a master-oscillator power-amplifier. The master oscillator is a commercial Nd:YVO(4) laser (1064 nm) which is capable of Q-switching at frequencies between 5 and 250 kHz. Four Nd:YAG (yttrium aluminum garnet) amplifier stages are in place to amplify the Nd:YVO(4) emission. Single pulses through the Nd:YAG amplifier stages gives energies up to 1.5 J and the gain for each stage has been measured. Repetitive pulsing at 10 kHz has also been performed for 2 ms bursts, giving average pulse energies of 0.53 J with ΔE/E of 4.6%, where ΔE is the standard deviation between pulses. The next step will be to add one of two Nd:glass (silicate) amplifier stages to produce final pulse energies of 1-2 J for bursts up to 250 kHz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-repetition-rate pulse-burst laser for Thomson scattering on the MST reversed-field pinch

A new, high-repetition-rate pulse-burst laser system for the MST Thomson scattering diagnostic has operated with 2 J pulses at repetition rates up to 75 kHz within a burst. The 1064 nm laser currently employs a q-switched, diode pumped Nd:YVO4 master oscillator, four Nd:YAG amplifier stages, and a Nd:glass amplifier, with plans for an additional Nd:glass amplifier. The laser can maintain 1.5–2 ...

متن کامل

Operation and beam profiling of an up to 200 kHz pulse-burst laser for Thomson scattering.

A new, high-repetition rate laser is in development for use on the Thomson scattering diagnostic on the Madison Symmetric Torus. The laser has been tested at a rate of 200 kHz in a pulse-burst operation, producing bursts of 5 pulses above 1.5 J each, while capable of bursts of 17 pulses at 100 kHz. A master oscillator-power amplifier architecture is used with a Nd:YVO4 oscillator, four Nd:YAG a...

متن کامل

Pulse-burst laser systems for fast Thomson scattering (invited).

Two standard commercial flashlamp-pumped Nd:YAG (YAG denotes yttrium aluminum garnet) lasers have been upgraded to "pulse-burst" capability. Each laser produces a burst of up to 15 2 J Q-switched pulses (1064 nm) at repetition rates of 1-12.5 kHz. Variable pulse-width drive (0.15-0.39 ms) of the flashlamps is accomplished by insulated gate bipolar transistor (IGBT) switching of electrolytic cap...

متن کامل

Energy-partition diagnostic for measuring time-resolved scattering and absorption in burst-mode laser ablation.

We describe an energy-partition diagnostic based on integrating sphere principle for measuring absorption and scattering in plasma-mediated ablation by a high repetition-rate (133 MHz), pulsetrain-burst ultrafast-pulse laser. The system time-resolves the partition of elastically scattered laser light into specular reflection, diffuse reflection, and transmission, giving access to per-pulse abso...

متن کامل

A Review of High Power Opcpa Technology for High Repetition Rate Free-electron Lasers∗

High repetition rate free-electron lasers (FEL) require the development of new laser systems that have the ability to operate at high average power. Optical parametric chirped-pulse amplification (OPCPA) is presently the most promising method to fulfill these requirements. This technique has been used to demonstrate amplification up to tens of watts with a repetition rate in the range between t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 10  شماره 

صفحات  -

تاریخ انتشار 2010