Sinoatrial block with complicating sinoatrial reciprocation.
نویسندگان
چکیده
This presentation reflects an atypical manifestation of sinoatrial block in a patient with chronic renal failure and hyperkalemia (7.8 mEq/L). An allorhythmic distribution of P-P intervals permits the interpretation of sinoatrial block complicated by sinoatrial reciprocation.
منابع مشابه
Sinoatrial block complicating legionnaire's disease.
A 59 year old woman presented with acute onset of fever, chills, diaphoresis, vague chest discomfort, and was found to be hypotensive and tachypnoeic. An electrocardiogram demonstrated sinoatrial block with a junctional rhythm between 50 and 80 beats/min. All cultures were negative and imaging studies unrevealing. Her urine tested positive for Legionella pneumophila antigen serotype 1 and she i...
متن کاملConcealed paroxysmal atrioventricular block: diffuse congenital atrioventricular conduction system disorder with nonpropagated His bundle depolarizations.
A 2 1/2-year-old girl with bradycardia and left bundle branch block at birth began to experience "night cries" when deeply asleep. Electrophysiological study demonstrated congenital diffuse atrioventricular conduction disease with concealed paroxysmal atrioventricular block, nonpropagated His bundle depolarizations, severe sinus node abnormality, and a low atrioventricular junctional escape rhy...
متن کاملSino-atrial reciprocation in the isolated rabbit heart.
Reciprocal beats between sinus node and atrium were studied in isolated rabbit heart tissue by microelectrode techniques. Early premature atrial responses which entered the sinus node frequently emerged to re-excite the atrium as "echoes." When the premature atrial beats discharged some but not all nodal areas, the atrial echoes, in turn, appeared to re-enter the sinus node. Repetitive reciproc...
متن کاملConcealed AV junctional extrasystoles simulating second-degree sinoatrial block.
Concealed AV junctional extrasystoles are described which, conducted in a restrograde manner to the sinoatrial junction, interfere with sinus impulses, thus simulating a second-degree, 2:1, sinoatrial block.
متن کاملSinoatrial block. Autonomic influences and clinical assessment.
Seventeen patient with sinoatrial block and 16 healthy volunteers were investigated with recently developed autonomic tests of atrial pacemaker function. Only one patients was found to be entirely normal in comparison with normal subjects, while another patients had supernormal responses. Fifteen patients had reduced responses relative to the controls implying impaired atrial pacemaker function...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 87 5 شماره
صفحات -
تاریخ انتشار 1985