Maximal treadmill exercise electrocardiography. Correlations with coronary arteriography and cardiac hemodynamics.
نویسندگان
چکیده
SUMMARY Electrocardiograms were recorded during and at 2-min intervals following maximal treadmill exercise in 100 patients and were correlated with coronary arteriograms, left ventricular cineangiograms, and resting and exercise cardiac hemodynamics. The incidence and extent of exercise-induced "ischemic" S-T segment depression increased significantly (P < 0.01) with increasing extent of coronary artery disease (CAD). A criterion of abnormality of 1.0 mm or greater S-T depression most accurately predicted the presence of CAD with a specificity (true negative) of 89% and a sensitivity (true positive) of 62%. Criteria of _0.75 and _0.5 mm S-T depression offered improved sensitivities (68 and 84%, respectively) but markedly reduced specificities (78 and 57%, respectively). A significant correlation (P < 0.005) was found between increasing extent of exercise-induced S-T segment depression and the pulmonary artery wedge pressure during exercise. There were no correlations between the presence or extent of exercise-induced S-T depression and the resting or exercise pulmonary artery pressure, cardiac index, stroke-volume index, or exercise factor, or the resting left ventricular dp/ dt, left ventricular end-diastolic pressure, left ventricular ejection fraction, or presence of asynergy on the left ventricular cineangiogram. The maximal treadmill exercise test provided a noninvasive method for predicting the presence and extent of significant CAD in the individual patient with chest pain. Although a normal treadmill exercise test provided little insight into the underlying resting and exercise hemodynamics, an abnormal treadmill test (_ 1.0 mm S-T depression) was associated with an abnormal increase in left ventricular filling pressure with exercise in 90% of the patients.
منابع مشابه
Evaluation of Myocardial Ischemic Damage
28. Nelson GR, Cohn PF, Gorlin R: Prognosis in medically treated coronary artery disease. Influence of ejection fraction compared to other parameters. Circulation 52: 408, 1975 29. Webster JS, Moberg C, Rincon G: Natural history of severe proximal coronary artery disease as documented by coronary cineangiography. Am J Cardiol 33: 195, 1974 30. Martin CM, McConahay DR: Maximal treadmill exercise...
متن کاملMyocardial imaging with thallium-201 at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography.
Myocardial imaging with intravenous thallium-201 (201Tl) was performed at rest and following maximal treadmill exercise in 101 patients with suspected coronary artery disease. Results were interpreted from Polaroid scintiphotos by three independent observers with complete interobserver agreement in 79%. Of 25 patients with no or insignificant coronary artery disease (less than 50% diameter sten...
متن کاملDiagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing.
A multicenter study was performed to compare the diagnostic accuracy of a new technique, seismocardiography, with that of electrocardiography for physiologically and anatomically significant ischemic coronary artery disease (CAD) during exercise stress testing. Five participating centers enrolled 129 patients who had simultaneous seismocardiograms and 12-lead electrocardiograms at the time of t...
متن کاملImproved Efficiency of Treadmill Exercise Testing Using a Multiple Lead ECG System and Basic Hemodynamic Exercise Response BERNARD
One hundred consecutive men with a normal ECG at rest had a maximal treadmill test using 14 leads during and postexercise. Coronary arteriography performed the following day revealed coronary stenoses k70% in 66 patients. Test results obtained from a V6 lead were compared to different lead combinations and were correlated with arteriographic findings. A positive exercise test occurred in 37 men...
متن کاملImproved efficiency of treadmill exercise testing using a multiple lead ECG system and basic hemodynamic exercise response.
One hundred consecutive men with a normal ECG at rest had a maximal treadmill test using 14 leads during and post-exercise. Coronary arteriography performed the following day revealed coronary stenoses greater than or equal to 70% in 66 patients. Test results obtained from a V5 lead were compared to different lead combinations and were correlated with arteriographic findings. A positive exercis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 46 5 شماره
صفحات -
تاریخ انتشار 1972