Linked color imaging (LCI), a novel image-enhanced endoscopy technology, emphasizes the color of early gastric cancer

نویسندگان

  • Hiromitsu Kanzaki
  • Ryuta Takenaka
  • Yoshiro Kawahara
  • Daisuke Kawai
  • Yuka Obayashi
  • Yuki Baba
  • Hiroyuki Sakae
  • Tatsuhiro Gotoda
  • Yoshiyasu Kono
  • Ko Miura
  • Masaya Iwamuro
  • Seiji Kawano
  • Takehiro Tanaka
  • Hiroyuki Okada
چکیده

Background and study aims  Linked color imaging (LCI) and blue laser imaging (BLI) are novel image-enhanced endoscopy technologies with strong, unique color enhancement. We investigated the efficacy of LCI and BLI-bright compared to conventional white light imaging (WLI) by measuring the color difference between early gastric cancer lesions and the surrounding mucosa. Patients and methods  Images of early gastric cancer scheduled for endoscopic submucosal dissection were captured by LCI, BLI-bright, and WLI under the same conditions. Color values of the lesion and surrounding mucosa were defined as the average of the color value in each region of interest. Color differences between the lesion and surrounding mucosa (ΔE) were examined in each mode. The color value was assessed using the CIE L*a*b* color space (CIE: Commission Internationale d'Eclairage). Results  We collected images of 43 lesions from 42 patients. Average ΔE values with LCI, BLI-bright, and WLI were 11.02, 5.04, and 5.99, respectively. The ΔE was significantly higher with LCI than with WLI ( P  < 0.001). Limited to cases of small ΔE with WLI, the ΔE was approximately 3 times higher with LCI than with WLI (7.18 vs. 2.25). The ΔE with LCI was larger when the surrounding mucosa had severe intestinal metaplasia ( P  = 0.04). The average color value of a lesion and the surrounding mucosa differed. This value did not have a sufficient cut-off point between the lesion and surrounding mucosa to distinguish them, even with LCI. Conclusion  LCI had a larger ΔE than WLI. It may allow easy recognition and early detection of gastric cancer, even for inexperienced endoscopists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linked color imaging improves endoscopic diagnosis of active Helicobacter pylori infection

BACKGROUND AND STUDY AIMS Linked color imaging (LCI) is a new image-enhanced endoscopy technique using a laser light source to enhance slight differences in mucosal color. The aim of this study was to compare the usefulness of LCI and conventional white light imaging (WLI) endoscopy for diagnosing Helicobacter pylori (H. pylori). PATIENTS AND METHODS We retrospectively analyzed images from 60...

متن کامل

Objective Endoscopic Analysis with Linked Color Imaging regarding Gastric Mucosal Atrophy: A Pilot Study

Objectives We aimed to determine whether linked color imaging (LCI), a new image-enhanced endoscopy that enhances subtle differences in mucosal colors, can distinguish the border of endoscopic mucosal atrophy. Methods This study included 30 patients with atrophic gastritis. In endoscopy, we continuously took images in the same composition with both LCI and white light imaging (WLI). In each i...

متن کامل

Therapeutic application of linked color imaging for colorectal endoscopic mucosal resection.

Linked color imaging (LCI; Fujifilm Co., Tokyo, Japan) is a newly developed image-enhanced technique that has shown high diagnostic performance in the field of gastrointestinal endoscopy. LCI enhances color separation of the mucosal layer, making red regions redder and white regions whiter. This contributes to the detection of gastric cancer [1], ulcerative colitis [2], colorectal polyps [3, 4]...

متن کامل

Laterally Spreading Tumor of the Rectum Delineated with Linked Color Imaging Technology.

Colonoscopy has been shown to decrease the incidence of colorectal cancer and cancer death through the removal of adenomatous polyps. To make an accurate diagnosis of colorectal neoplasms, several image-enhanced endoscopic systems, such as narrow band imaging (NBI), flexible spectral imaging color enhancement, and blue laser imaging (BLI), have been developed. However, no significant difference...

متن کامل

Linked-color imaging combined with the NICE classification system for optical diagnosis of colon polyps: new image-enhanced endoscopic technology for pathological prediction

INTRODUCTION Linked-color imaging (LCI) is a recently developed system used in endoscopy. It creates clear and bright endoscopic images using short-wavelength, narrow-band laser light combined with white laser light. The illuminating light and signal processing emphasize slight color differences in abnormal regions that approximate the normal color of the mucosa. As a result, regions initially ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017