The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem

نویسندگان

  • Young-Yool Chung
  • Chae-Hyun Im
  • Dae-Hee Kim
  • Ju-Yeong Heo
  • Young-Jae Jang
چکیده

PURPOSE To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of ≥12 years. MATERIALS AND METHODS From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosthesis. The average age at the time of surgery was 53.4 years and the mean duration of follow-up was 17.1 years (range, 12.1-21.0 years). The Harris hip score (HHS) and radiographic assessments of thigh pain were used to evaluate the clinical results. We observed osteointegration, cortical hypertrophy, reactive line, calcar resorption and osteolysis around the femoral stems. The survival rate of the femoral stems was evaluated by using the span of time to a revision operation for any reasons was defined as the end point. RESULTS The mean HHS was 50.5 preoperatively and 84.2 at the time of last follow-up. Osteolysis only around the HA-coated proximal portion of the femoral stem was observed in 72 hips, cortical hypertrophy all around the distal portion of the femoral stem was observed in 38 hips, and calcar resorption was observed in 44 hips. A reactive line was observed in 13 hips, but was unrelated to component loosening. Stem revision operations were performed in 24 (23%) hips due to osteolysis (14 hips), fracture (5 hips) and infection (5 hips). The femoral stem survival rate was 75% over the mean duration of follow-up. CONCLUSION Total hip arthroplasty using a HA-coated anatomical femoral stem showed necessitated a high rate of revision operations due to osteolysis around the femoral stem in this long term follow-up study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of hydroxyapatite coating on survival of an uncemented femoral stem

BACKGROUND AND PURPOSE Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA...

متن کامل

Results of a hydroxyapatite-coated femoral stem (Corail) in Chinese: a minimum 10-year follow-up

BACKGROUND Due to the adverse effects of cemented hip arthroplasty, uncemented stems with hydroxyapatite (HA) coating reduces these risks and enhanced integration. The concept of an extensive HA coating for the fixation of a tapered femoral stem (Corail®) was introduced, which can achieve durable biological fixation and preserve normal periprosthetic bone activity. Here we describe the clinical...

متن کامل

Hydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival.

The purpose of this study was to evaluate the long-term clinical outcomes of primary total hip arthroplasty using an uncemented, hydroxyapatite-coated implant. We followed a consecutive series of 164 patients, who underwent total hip arthroplasty with the Furlong fully-hydroxyapatite coated implant over a mean time period of 12.8 years. Clinical and radiological analyses were performed. Roentge...

متن کامل

Does hydroxyapatite coating have no advantage over porous coating in primary total hip arthroplasty? A meta-analysis

There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible y...

متن کامل

Fixation of the fully hydroxyapatite-coated Corail stem implanted due to femoral neck fracture

BACKGROUND Today, dislocated femoral neck fractures are commonly treated with a cemented hip arthroplasty. However, cementing of the femoral component may lead to adverse effects and even death. Uncemented stems may lower these risks and hydroxyapatite (HA) coating may enhance integration, but prosthetic stability and clinical outcome in patients with osteoporotic bone have not been fully explo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2014