Effects of Nano-Hydroxyapatite/Polyetheretherketone-Coated, Sandblasted, Large-Grit, and Acid-Etched Implants on Inflammatory Cytokines and Osseointegration in a Peri-Implantitis Model in Beagle Dogs
نویسندگان
چکیده
BACKGROUND This study explored the effects of nano-hydroxyapatite/polyetheretherketone (n-HA/PEEK)- coated sandblasted, large-grit, and acid-etched (SLA) implants on inflammatory cytokines and osseointegration in peri-implantitis model beagle dogs. MATERIAL AND METHODS Peri-implantitis models were established. Eight beagle dogs were randomly and evenly assigned into SLA tied, SLA + n-HA/PEEK tied, SLA untied, or SLA + n-HA/PEEK untied groups. A special periodontal probe was used to detect the plaque index (PLI), probing depth (PD), and modified Sulcus Bleeding Index (mSBI). Gingival crevicular fluid was collected and an ELISA kit was utilized to detect IL-1, IL-6, and IL-17 levels. The colony-forming units were counted and the maximum shear strength of implants was tested using the axial pullout test. HE staining was used to detect the inflammation of peri-implant bone tissues. Osseointegration was observed through toluidine blue staining. Bone-to-implant contact (BIC) was obtained through histological observation and the mineral apposition rate (MAR) was calculated after immune fluorescent double staining. RESULTS The SLA tied group demonstrated higher levels of PLI, PD, mSBI, IL-1, IL-6, and IL-17 and a higher degree of inflammation than the SLA + n-HA/PEEK tied group. The tied groups also displayed similar results over the untied groups at the same time point. The maximum shear strength, BIC, and MAR in the SLA tied group were significantly lower than in the SLA + n-HA/PEEK tied group. CONCLUSIONS Our findings demonstrate that SLA + n-HA/PEEK implants can promote osseointegration and relieve the inflammation response of peri-implantitis in beagle dogs.
منابع مشابه
Evaluation of three different dental implants in ligature-induced peri-implantitis in the beagle dog. Part II. Histology and microbiology.
The purpose of this study was to evaluate experimental peri-implant breakdown microbiologically, radiographically and histologically. Hydroxyapatite-coated, titanium plasma-sprayed, and titanium alloy surfaces were investigated. Eighty-four implants were placed in 14 beagle dogs. Standardized radiographs and microbiologic samples (DNA) were obtained. Dogs were sacrificed at 3 and 6 months. Unde...
متن کاملBcp® Surface Treatment
Implants were placed in the femurs of miniature pigs. After 3 and 6 weeks respectively, the implants were removed and analyzed. Signifi cant differences were noted in the percentage of B.I.C. (Bone Implant Contact). Polished, sandblasted with fi ne grit, or acid etched implant surfaces had the lowest percentage of B.I.C. (B.I.C. < 25%). Grit-blasted (coarse grit) or T.P.S. (Titanium Plasma Spra...
متن کاملAcid Etching and Plasma Sterilization Fail to Improve Osseointegration of Grit Blasted Titanium Implants
Interaction between implant surface and surrounding bone influences implant fixation. We attempted to improve the bone-implant interaction by 1) adding surface micro scale topography by acid etching, and 2) removing surface-adherent pro-inflammatory agents by plasma cleaning. Implant fixation was evaluated by implant osseointegration and biomechanical fixation.The study consisted of two paired ...
متن کاملEffects of rhBMP-2 on Sandblasted and Acid Etched Titanium Implant Surfaces on Bone Regeneration and Osseointegration: Spilt-Mouth Designed Pilot Study
This study was conducted to evaluate effects of rhBMP-2 applied at different concentrations to sandblasted and acid etched (SLA) implants on osseointegration and bone regeneration in a bone defect of beagle dogs as pilot study using split-mouth design. Methods. For experimental groups, SLA implants were coated with different concentrations of rhBMP-2 (0.1, 0.5, and 1 mg/mL). After assessment of...
متن کاملMicro-arc Oxidation (MAO) Coupling Electrophoresis Deposition (EPD) Versus Hydroxyapatite Coating in Periimplantitis: An Experimental Study in Dog
Object: This paper aims to evaluate the influence of dental implants coated with hydroxyapatite (HA) and implants processed by micro-arc oxidation (MAO) coupling electrophoresis deposition (EPD) on experimental peri-implantitis in Beagle dogs. Methods: The thirty-six implants (diameter 3.3 mm & length 11 mm) were equally divided into three groups. Group A was processed with a plasma-sprayed lay...
متن کامل