Autoantibody detection using indirect immunofluorescence on HEp-2 cells.

نویسندگان

  • Ulrich Sack
  • Karsten Conrad
  • Elena Csernok
  • Ingrid Frank
  • Falk Hiepe
  • Thorsten Krieger
  • Arno Kromminga
  • Philipp von Landenberg
  • Gerald Messer
  • Torsten Witte
  • Rudolf Mierau
چکیده

The detection of autoantibodies is an important element in the diagnosis and monitoring of disease progression in patients with autoimmune diseases. In laboratory diagnostic tests for connective tissue and autoimmune liver diseases, indirect immunofluorescence on HEp-2 cells plays a central role in a multistage diagnostic process. Despite the high quality of diagnostics, findings at different laboratories can differ considerably due to a lack of standardization, as well as subjective factors. The present paper formulates recommendations for the standardized processing and interpretation of the HEp-2 cell test for the detection of non-organ-specific (especially antinuclear) antibodies. It provides requirements regarding the diagnostic tests used, instructions for laboratory procedure and evaluation, and recommendations for interpretation. For an optimal laboratory diagnostic process, it is useful to have an informative, tentative clinical diagnosis and an experienced laboratory diagnostician. In addition, the following key elements are recommended: initial screening using indirect immunofluorescence on carefully chosen HEp-2 cells beginning with a serum dilution of 1:80 and evaluation under a microscope with powerful illumination; results from a titer of 1:160 upwards being considered positive; internal laboratory quality control; and standardized interpretation. The aim is to improve diagnostic tests and care of patients with autoimmune diseases as a central concern of the European Autoimmunity Standardization Initiative (EASI).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated evaluation of autoantibodies on human epithelial-2 cells as an approach to standardize cell-based immunofluorescence tests

INTRODUCTION Analysis of autoantibodies (AAB) by indirect immunofluorescence (IIF) is a basic tool for the serological diagnosis of systemic rheumatic disorders. Automation of autoantibody IIF reading including pattern recognition may improve intra- and inter-laboratory variability and meet the demand for cost-effective assessment of large numbers of samples. Comparing automated and visual inte...

متن کامل

Anticytoskeletal Autoantibody to Microfilament Novel Focal Contact Proteins Anchorage Sites Recognizes

Actin microfilaments are anchored to the plasma membrane at focal contacts. Using an indirect immunofluorescence method, we detected an autoantibody reactive with focal contacts in PtK2, HEp-2, and BHK-21 cells in serum from two patients with early systemic sclerosis. With double immunofluorescence, using the actin-binding drug phalloidin, we localized the plaques decorated by these sera specif...

متن کامل

Routine immunofluorescence detection of Ro/SS-A autoantibody using HEp-2 cells transfected with human 60 kDa Ro/SS-A.

BACKGROUND Ro/SS-A autoantibodies associated with systemic lupus erythematosus (SLE) and Sjögren syndrome may be missed during routine screening for antinuclear autoantibodies (ANA) by immunofluorescence using HEp-2 cells. AIMS To investigate the use of HEp-2 cells transfected with human 60 kDa Ro/SS-A for routine detection of these antibodies. METHODS 10,500 sera were screened at a dilutio...

متن کامل

Detection of specific antinuclear reactivities in patients with negative anti-nuclear antibody immunofluorescence screening tests.

BACKGROUND For detection of anti-nuclear antibodies (ANAs) and antibodies to extractable nuclear antigens (ENAs), samples frequently are screened with indirect immunofluorescence (IIF); further determination of anti-ENA antibodies is performed only when the result is positive. However, because anti-ENA reactivities are found in samples with low fluorescence intensities, we determined anti-ENA a...

متن کامل

Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies

INTRODUCTION Autoantibodies to the ribosomal P proteins represent a highly specific marker for the diagnosis of systemic lupus erythematosus, where they have been associated with certain clinical manifestations. Historically, autoantibodies against ribosomal P proteins have been detected by indirect immunofluorescence, immunodiffusion, immunoblot, and other immunoassays. More recently, enzyme-l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the New York Academy of Sciences

دوره 1173  شماره 

صفحات  -

تاریخ انتشار 2009