Validity and reliability of ankle morphological measurements on computerized tomography-synthesized planar radiographs
نویسندگان
چکیده
BACKGROUND Clinical success of total ankle arthroplasty depends heavily on the available information on the morphology of the bones, often obtained from measurements on planar radiographs. The current study aimed to evaluate the intra-rater, inter-rater and inter-session reliability and the validity of radiograph-based measurements of ankle morphology, and to quantify the effects of examiner experience on these measurements. METHODS Twenty-four fresh frozen ankle specimens were CT scanned, data of which were used to reconstruct 3D volumetric bone models for synthesizing 2D radiographs. Two orthopaedic surgeons with different levels of clinical experience identified twenty landmarks five times on each of the synthesized sagittal and coronal radiographs and repeated the test on a subsequent day within 5 days. The landmarks were used to calculate fourteen morphological parameters. The two-way mixed-effects (ICC3,1), two-way random-effects (ICC2,k) and two-way random-effects (ICC3,k) models were used, respectively, to assess the intra-rater, inter-rater and inter-session reliability of measurements. The validity of the measurements for each examiner was assessed by comparing them with gold standard values obtained from the 2D radiographs projected from the 3D volumetric models using Pearson's correlation analysis and Bland and Altman plots, and the differences were defined as the measurement errors. RESULTS Most of the morphological parameters were of good to very good intra-rater, inter-session and inter-rater reliability for both examiners (ICC > 0.61). Experience appeared to affect the inter-rater and inter-session reliability, the senior examiner showing greater inter-session ICC values than the junior examiner. Most of the tibial parameters had moderate to excellent correlations with the corresponding gold standard values but were underestimated by both examiners, in contrast to most of the talar parameters that were overestimated and had only poor to fair correlations. CONCLUSIONS Most of the morphological parameters of the ankle can be estimated from radiographs with good to very good intra-rater, inter-session and inter-rater reliability, for both clinically experienced and less experienced examiners. Clinical experience helped increase the reliability of repeated evaluations after a longer interval, such as in a follow-up assessment. It is suggested that critical clinical decisions based on repeated morphology measurements should be made by more experienced surgeons or after appropriate training.
منابع مشابه
Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
BACKGROUND Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint during imaging. The current study aimed to compare ankle morphological measurements using CT-generated ...
متن کاملReliability of Postoperative Radiographies in Ankle Fractures
Background: The accuracy of reduction of ankle fractures using postoperative plain radiographies (x-ray) remainswidely controversial. Some authors have demonstrated that postoperative computed tomography (CT) scan can beuseful for these patients. In current study, the efficacy of x-rays after fixation of ankle fractures was investigated basedon the CT scan findings.Metho...
متن کاملRadiographic evaluation of the ankle syndesmosis.
BACKGROUND Radiographic measurements to document ankle anatomy have been suggested in recent literature to be inadequate. Focus has been put on stress views and computed tomography; however, there are also issues with these modalities. An orthogonal view that could be used both statically and dynamically could help determine syndesmotic stability. The purpose of this study was to determine a pa...
متن کاملThe Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible
Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...
متن کاملComparison of Cone Beam Computerized Tomography and Phosphor Storage Plate in Detecting Artificial Buccal Recurrent Caries
Introduction Recurrent or secondary caries develops at the margin of restorations and causes restorative failure. We conducted this study to compare the performance of Phosphor Storage Plate (PSP) and Cone Beam Computed Tomography (CBCT) scan in detecting buccal recurrent caries under amalgam and composite resin restorations. Materials and Methods Class V cavities were prepared on the buccal...
متن کامل