Unleash Stranded Power in Data Centers with Rack Packing

ثبت نشده
چکیده

Data center infrastructures are highly underutilized on average. Typically, a data center manager computes the number of servers his facility can host by dividing the total power capacity of each rack by an assigned “peak power rating” for each server. However, this scheme suffers from the weakness of all static provisioning schemes – it does not account for the variability of load on the servers. We propose an algorithm that studies the power consumption behavior of the servers over time and suggests optimal ways to combine them in racks to maximize rack power utilization. The server placement problem is a version of vector bin packing [2], and our solution – RackPacker – approximates a near-optimal solution efficiently using a number of domain-specific optimizations. One of the central insights we use is that the different servers hosting a single application typically show strongly correlated, but often somewhat time-shifted, power consumption behavior. Hence, we find servers that show anticorrelated, or strongly time-shifted behavior and pack them together to maximize rack utilization. Our initial experiments with RackPacker show substantially superior results than static packing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unleash Stranded Power in Data Centers with RackPacker

Data center infrastructures are highly underutilized on average. Typically, a data center manager computes the number of servers his facility can host by dividing the total power capacity of each rack by an assigned “peak power rating” for each server. However, this scheme suffers from the weakness of all static provisioning schemes – it does not account for the variability of load on the serve...

متن کامل

UPS-Aware Workload Placement in Enterprise Data Centers

Energy efficiency has become a very important concern for enterprise data centers due to the significant cost on electricity. To improve the energy efficiency of data centers, researchers and practitioners have proposed enormous work to reduce the energy consumption of data centers. Most of previous work focus on reducing the energy consumption of IT equipment; however, the power losses caused ...

متن کامل

CloudPowerCap: Integrating Power Budget and Resource Management across a Virtualized Server Cluster

In many data centers, server racks are highly underutilized. Rack slots are left empty to keep the sum of the server nameplate maximum power below the power provisioned to the rack, while the servers placed in the rack cannot make full use of available rack power. The root cause of this rack underutilization is that the server nameplate power is often much higher than can be reached in practice...

متن کامل

The Advantages of Row and Rack - Oriented Cooling Architectures for Data Centers

Room cooling is an ineffective approach for next-generation data centers. Latest generation high density and variable density IT equipment create conditions that room cooling was never intended to address, resulting in cooling systems that are inefficient, unpredictable, and low in power density. Row-oriented and rack-oriented cooling architectures have been developed to address these problems....

متن کامل

Fuel Cells for Data Centers: Power Generation Inches From the Server

Typically, improving data center availability requires designing in more infrastructure; the antithesis of reducing costs. Is there a way to cut infrastructure, cost and emissions while improving energy efficiency and server availability? We consider and evaluate the integration of fuel cells with IT hardware with various architectural designs, essentially collapsing the entire energy supply ch...