Noninvasive detection of pulmonary hypertension in patent ductus arteriosus by pulsed Doppler echocardiography.

نویسندگان

  • J G Stevenson
  • I Kawabori
  • W G Guntheroth
چکیده

Twenty-five patients with proven patent ductus arteriosus were examined by pulsed Doppler echocardiography (PDE) before invasive assessment. Ten patients had normal pulmonary artery pressures, and by PDE, pandiastolic ductal flow. Fifteen patients had elevation of mean pulmonary artery pressure, and by PDE, all had abbreviations of diastolic ductal flow. PDE correctly distinguished between patients with normal pressure and those with evidence of pulmonary hypertension; the ECG did not allow such differentiation. Detection by PDE of pulmonary hypertension complicating patent ductus arteriosus appears to be clinically useful.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus.

The pulsed Doppler technique was used to record the flow velocity patterns in the ductus arteriosus and the pulmonary artery in 26 patients with either isolated or complicated patent ductus arteriosus (PDA). In all patients, abnormal Doppler signals indicating left-to-right (L-R) or right-to-left shunt flow or both could be obtained at the site of the ductus arteriosus. These Doppler flow patte...

متن کامل

DIAGNOSTIC METHODS CONGENITAL HEART DISEASE Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus

The pulsed Doppler technique was used to record the flow velocity patterns in the ductus arteriosus and the pulmonary artery in 26 patients with either isolated or complicated patent ductus arteriosus (PDA). In all patients, abnormal Doppler signals indicating left-to-right (L-R) or right-to-left shunt flow or both could be obtained at the site of the ductus arteriosus. These Doppler flow patte...

متن کامل

Detection and quantitation of constriction of the fetal ductus arteriosus by Doppler echocardiography.

Pulmonary hypertension may occur in the fetus in the presence of constriction of the ductus arteriosus. The feasibility of detection and quantitation of fetal ductal constriction by Doppler echocardiography was assessed in an animal preparation in which ductal constriction was created in the fetal lamb with a variable ligature causing varying degrees of fetal pulmonary hypertension (fetal pulmo...

متن کامل

Pulmonary regurgitation studied with the ultrasonic pulsed Doppler technique.

Sixty patients with pulmonary regurgitation were studied by the pulsed Doppler technique combined with two-dimensional and M-mode echocardiography. Patients with pulmonary regurgitation had abnormal Doppler signals just below the pulmonic valve in the right ventricular outflow tract in diastole on the two-dimensional image. These signals were considered to indicate the regurgitant flow. There a...

متن کامل

Patent ductus arteriosus.

Patent ductus arteriosus (PDA) is a congenital disorder in heart, wherein the ductus arteriosus fails to close after birth. This leads to the generation of a left-to-right shunt, leading to pulmonary hypertension. Color Doppler echocardiography is essential for the diagnosis. The identification of a diastolic flow oriented in the opposite direction in the pulmonary artery finalizes the diagnosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 60 2  شماره 

صفحات  -

تاریخ انتشار 1979